Packed Record TPVSystem2Vars

Hierarchy
Methods
Properties

Unit

Declaration

type TPVSystem2Vars = packed record

Description

propkvarLimitneg Struct to pass basic data to user-written DLLs

Overview

Fields

Public FkVArating: Double;
Public kVPVSystemBase: Double;
Public RThev: Double;
Public XThev: Double;
Public Vthevharm: Double;
Public VthevmagDyn: Double;
Public Thetaharm: Double;
Public ThetaDyn: Double;
Public InitialVAngle: Double;
Public EffFactor: Double;
Public TempFactor: Double;
Public PanelkW: Double;
Public FTemperature: Double;
Public FPmpp: Double;
Public FpuPmpp: Double;
Public FIrradiance: Double;
Public MaxDynPhaseCurrent: Double;
Public Fkvarlimit: Double;
Public Fkvarlimitneg: Double;
Public Vreg: Double;
Public Vavg: Double;
Public VVOperation: Double;
Public VWOperation: Double;
Public DRCOperation: Double;
Public VVDRCOperation: Double;
Public WPOperation: Double;
Public WVOperation: Double;
Public NumPhases: Integer;
Public NumConductors: Integer;
Public Conn: Integer;
Public P_Priority: LongBool;
Public PF_Priority: LongBool;

Description

Fields

Public FkVArating: Double;
 
Public kVPVSystemBase: Double;
 
Public RThev: Double;
 
Public XThev: Double;
 
Public Vthevharm: Double;
 
Public VthevmagDyn: Double;

Thevinen equivalent voltage mag for Harmonic model

Public Thetaharm: Double;

Thevinen equivalent voltage mag reference for Dynamics model

Public ThetaDyn: Double;

Thevinen equivalent angle reference for Harmonic model

Public InitialVAngle: Double;

Thevinen equivalent angle reference for Dynamics model

Public EffFactor: Double;

initial terminal voltage angle when entering dynamics mode

Public TempFactor: Double;
 
Public PanelkW: Double;
 
Public FTemperature: Double;

computed

Public FPmpp: Double;
 
Public FpuPmpp: Double;
 
Public FIrradiance: Double;
 
Public MaxDynPhaseCurrent: Double;
 
Public Fkvarlimit: Double;
 
Public Fkvarlimitneg: Double;

maximum kvar output of the PVSystem (unsigned)

Public Vreg: Double;

Variables set from InvControl. They are results of monitor in mode 3

Public Vavg: Double;

will be set from InvControl or ExpControl

Public VVOperation: Double;
 
Public VWOperation: Double;
 
Public DRCOperation: Double;
 
Public VVDRCOperation: Double;
 
Public WPOperation: Double;
 
Public WVOperation: Double;
 
Public NumPhases: Integer;

kW_out_desired :Double; 32-bit integers

Public NumConductors: Integer;

Number of phases

Public Conn: Integer;

Total Number of conductors (wye-connected will have 4)

Public P_Priority: LongBool;

0 = wye; 1 = Delta

Public PF_Priority: LongBool;

default False // added 10/30/2018