Packed Record TStorage2Vars
Unit
Declaration
type TStorage2Vars = packed record
Description
propDEBUGTRACE Struct to pass basic data to user-written DLLs
Overview
Fields
![]() |
kWrating: Double; |
![]() |
kWhRating: Double; |
![]() |
kWhStored: Double; |
![]() |
kWhReserve: Double; |
![]() |
ChargeEff: Double; |
![]() |
DisChargeEff: Double; |
![]() |
kVStorageBase: Double; |
![]() |
RThev: Double; |
![]() |
XThev: Double; |
![]() |
FkVArating: Double; |
![]() |
Fkvarlimit: Double; |
![]() |
Fkvarlimitneg: Double; |
![]() |
P_Priority: LongBool; |
![]() |
PF_Priority: LongBool; |
![]() |
pctkWrated: Double; |
![]() |
EffFactor: Double; |
![]() |
Vreg: Double; |
![]() |
Vavg: Double; |
![]() |
VVOperation: Double; |
![]() |
VWOperation: Double; |
![]() |
DRCOperation: Double; |
![]() |
VVDRCOperation: Double; |
![]() |
WPOperation: Double; |
![]() |
WVOperation: Double; |
![]() |
Vthev: Complex; |
![]() |
ZThev: Complex; |
![]() |
Vthevharm: Double; |
![]() |
Thetaharm: Double; |
![]() |
VthevMag: Double; |
![]() |
Theta: Double; |
![]() |
w_grid: Double; |
![]() |
TotalLosses: Double; |
![]() |
IdlingLosses: Double; |
![]() |
NumPhases: Integer; |
![]() |
NumConductors: Integer; |
![]() |
Conn: Integer; |
Description
Fields
![]() |
kWrating: Double; |
![]() |
kWhRating: Double; |
![]() |
kWhStored: Double; |
![]() |
kWhReserve: Double; |
![]() |
ChargeEff: Double; |
![]() |
DisChargeEff: Double; |
![]() |
kVStorageBase: Double; |
![]() |
RThev: Double; |
![]() |
XThev: Double; |
![]() |
FkVArating: Double; |
|
Inverter Related Properties | |
![]() |
Fkvarlimit: Double; |
![]() |
Fkvarlimitneg: Double; |
![]() |
P_Priority: LongBool; |
![]() |
PF_Priority: LongBool; |
![]() |
pctkWrated: Double; |
![]() |
EffFactor: Double; |
![]() |
Vreg: Double; |
|
Interaction with InvControl | |
![]() |
Vavg: Double; |
![]() |
VVOperation: Double; |
![]() |
VWOperation: Double; |
![]() |
DRCOperation: Double; |
![]() |
VVDRCOperation: Double; |
![]() |
WPOperation: Double; |
![]() |
WVOperation: Double; |
![]() |
Vthev: Complex; |
|
kW_out_desired :Double; Dynamics variables | |
![]() |
ZThev: Complex; |
|
Thevenin equivalent voltage (complex) for dynamic model | |
![]() |
Vthevharm: Double; |
![]() |
Thetaharm: Double; |
|
Thevenin equivalent voltage mag and angle reference for Harmonic model | |
![]() |
VthevMag: Double; |
|
Thevenin equivalent voltage mag and angle reference for Harmonic model | |
![]() |
Theta: Double; |
|
Thevenin equivalent voltage for dynamic model | |
![]() |
w_grid: Double; |
|
Power angle between voltage and current | |
![]() |
TotalLosses: Double; |
|
Grid frequency | |
![]() |
IdlingLosses: Double; |
![]() |
NumPhases: Integer; |
|
32-bit integers | |
![]() |
NumConductors: Integer; |
|
Number of phases | |
![]() |
Conn: Integer; |
|
Total Number of conductors (wye-connected will have 4) | |
Generated by PasDoc 0.16.0.