IndMach012#
( Circuit Element, PC Element )
EPRI’s OpenDSS Documentation for this component: https://opendss.epri.com/IndMach012.html
# |
Name |
Type |
Default |
Units |
Description |
---|---|---|---|---|---|
1 |
|
integer |
3 |
Number of Phases, this Induction Machine. |
|
2 |
|
string |
Bus to which the Induction Machine is connected. May include specific node specification. |
||
3 |
|
real |
12.47 |
kV |
Nominal rated (1.0 per unit) voltage, kV. For 2- and 3-phase machines, specify phase-phase kV. Otherwise, specify actual kV across each branch of the machine. If wye (star), specify phase-neutral kV. If delta or phase-phase connected, specify phase-phase kV. |
4 |
|
real |
1000.0 |
Shaft Power, kW, for the Induction Machine. A positive value denotes power for a load. |
|
5 |
|
real |
[Read Only] Present power factor for the machine. |
||
6 |
|
string |
Delta |
Connection of stator: Delta or Wye. Default is Delta. |
|
7 |
|
real |
1200.0 |
Rated kVA for the machine. |
|
8 |
|
real |
1.0 |
Per unit mass constant of the machine. MW-sec/MVA. |
|
9 |
|
real |
1.0 |
Damping constant. Usual range is 0 to 4. Adjust to get damping in Dynamics mode, |
|
10 |
|
real |
0.005 |
Per unit stator resistance. |
|
11 |
|
real |
0.106 |
Per unit stator leakage reactance. |
|
12 |
|
real |
0.007 |
Per unit rotor resistance. |
|
13 |
|
real |
0.12 |
Per unit rotor leakage reactance. |
|
14 |
|
real |
4.0 |
Per unit magnetizing reactance. |
|
15 |
|
real |
0.007 |
Initial slip value. |
|
16 |
|
real |
0.1 |
Max slip value to allow. Set this before setting slip. |
|
17 |
|
string |
VariableSlip |
Option for slip model. |
|
18 |
|
string |
LOADSHAPE object to use for yearly simulations. Must be previously defined as a Loadshape object. Is set to the Daily load shape when Daily is defined. The daily load shape is repeated in this case. Set Status=Fixed to ignore Loadshape designation. Set to NONE to reset to no loadshape. The default is no variation. |
||
19 |
|
string |
LOADSHAPE object to use for daily simulations. Must be previously defined as a Loadshape object of 24 hrs, typically. Set Status=Fixed to ignore Loadshape designation. Set to NONE to reset to no loadshape. Default is no variation (constant) if not defined. Side effect: Sets Yearly load shape if not already defined. |
||
20 |
|
string |
LOADSHAPE object to use for duty cycle simulations. Must be previously defined as a Loadshape object. Typically would have time intervals less than 1 hr. Designate the number of points to solve using the Set Number=xxxx command. If there are fewer points in the actual shape, the shape is assumed to repeat.Set to NONE to reset to no loadshape. Set Status=Fixed to ignore Loadshape designation. Defaults to Daily curve If not specified. |
||
21 |
|
boolean |
False |
Write DebugTrace file. |
|
22 |
|
string |
default |
Name of harmonic voltage or current spectrum for this IndMach012. Voltage behind Xd” for machine - default. |
|
23 |
|
real |
Hz |
Base Frequency for ratings. |
|
24 |
|
boolean |
True |
Indicates whether this element is enabled. |
|
25 |
|
string |
Make like another object, e.g.: |
Enumerations#
IndMach012: Slip Option#
Value |
---|
|
|