![]() | Bus Properties |
[This is preliminary documentation and is subject to change.]
The Bus type exposes the following members.
Name | Description | |
---|---|---|
![]() | AllPCEatBus |
Returns an array with the names of all PCE connected to the active bus
|
![]() | AllPDEatBus |
Returns an array with the names of all PDE connected to the active bus
|
![]() | Coorddefined |
False=0 else True. Indicates whether a coordinate has been defined for this bus
|
![]() | CplxSeqVoltages |
Complex Double array of Sequence Voltages (0, 1, 2) at this Bus.
|
![]() | Cust_Duration |
Accumulated customer outage durations
|
![]() | Cust_Interrupts |
Annual number of customer-interruptions from this bus
|
![]() | Distance |
Distance from energymeter (if non-zero)
|
![]() | Int_Duration |
Average interruption duration, hr.
|
![]() | Isc |
Short circuit currents at bus; Complex Array.
|
![]() | ItemInt32 | |
![]() | ItemString | |
![]() | kVBase |
Base voltage at bus in kV
|
![]() | Lambda |
Accumulated failure rate downstream from this bus; faults per year
|
![]() | LineList |
List of strings: Full Names of LINE elements connected to the active bus.
|
![]() | LoadList |
List of strings: Full Names of LOAD elements connected to the active bus.
|
![]() | N_Customers |
Total numbers of customers served downline from this bus
|
![]() | N_interrupts |
Number of interruptions this bus per year
|
![]() | Name |
Name of Bus
|
![]() | Nodes |
Integer Array of Node Numbers defined at the bus in same order as the voltages.
|
![]() | NumNodes |
Number of Nodes this bus.
|
![]() | puVLL |
Returns Complex array of pu L-L voltages for 2- and 3-phase buses. Returns -1.0 for 1-phase bus. If more than 3 phases, returns only 3 phases.
|
![]() | puVmagAngle |
Array of doubles containig voltage magnitude, angle pairs in per unit
|
![]() | puVoltages |
Complex Array of pu voltages at the bus.
|
![]() | SectionID |
Integer ID of the feeder section in which this bus is located.
|
![]() | SeqVoltages |
Double Array of sequence voltages at this bus.
|
![]() | TotalMiles |
Total length of line downline from this bus, in miles. For recloser siting algorithm.
|
![]() | VLL |
For 2- and 3-phase buses, returns array of complex numbers represetin L-L voltages in volts. Returns -1.0 for 1-phase bus. If more than 3 phases, returns only first 3.
|
![]() | VMagAngle |
Array of doubles containing voltages in Magnitude (VLN), angle (deg)
|
![]() | Voc |
Open circuit voltage; Complex array.
|
![]() | Voltages |
Complex array of voltages at this bus.
|
![]() | x |
X Coordinate for bus (double)
|
![]() | y |
Y coordinate for bus(double)
|
![]() | YscMatrix |
Complex array of Ysc matrix at bus. Column by column.
|
![]() | Zsc0 |
Complex Zero-Sequence short circuit impedance at bus.
|
![]() | ZSC012Matrix |
Array of doubles (complex) containing the complete 012 Zsc matrix
|
![]() | Zsc1 |
Complex Positive-Sequence short circuit impedance at bus..
|
![]() | ZscMatrix |
Complex array of Zsc matrix at bus. Column by column.
|