altdss.Fault
#
Module Contents#
Classes#
dict() -> new empty dictionary dict(mapping) -> new dictionary initialized from a mapping object’s (key, value) pairs dict(iterable) -> new dictionary initialized as if via: d = {} for k, v in iterable: d[k] = v dict(**kwargs) -> new dictionary initialized with the name=value pairs in the keyword argument list. For example: dict(one=1, two=2) |
|
dict() -> new empty dictionary dict(mapping) -> new dictionary initialized from a mapping object’s (key, value) pairs dict(iterable) -> new dictionary initialized as if via: d = {} for k, v in iterable: d[k] = v dict(**kwargs) -> new dictionary initialized with the name=value pairs in the keyword argument list. For example: dict(one=1, two=2) |
|
API#
- class altdss.Fault.Fault(api_util, ptr)#
Bases:
altdss.DSSObj.DSSObj
,altdss.CircuitElement.CircuitElementMixin
,altdss.PDElement.PDElementMixin
- AccumulatedL() float #
Accumulated failure rate for this branch on downline.
Requires a previous call to
RelCalc
commandOriginal COM help: https://opendss.epri.com/AccumulatedL.html
- BaseFreq: float#
‘property(…)’
Base Frequency for ratings.
DSS property name:
BaseFreq
, DSS property index: 15.
- Bus1: str#
‘property(…)’
Name of first bus. Examples:
bus1=busname bus1=busname.1.2.3
Bus2 automatically defaults to busname.0,0,0 unless it was previously defined.
DSS property name:
Bus1
, DSS property index: 1.
- Bus2: str#
‘property(…)’
Name of 2nd bus of the 2-terminal Fault object. Defaults to all phases connected to first bus, node 0, if not specified. (Shunt Wye Connection to ground reference)
That is, the Fault defaults to a ground fault unless otherwise specified.
DSS property name:
Bus2
, DSS property index: 2.
- Close(terminal: int, phase: int) None #
Close the specified terminal and phase, if non-zero, or all conductors at the terminal.
Original COM help: https://opendss.epri.com/Close1.html
- ComplexSeqCurrents() altdss.types.ComplexArray #
Complex double array of Sequence Currents for all conductors of all terminals of active circuit element.
Original COM help: https://opendss.epri.com/CplxSeqCurrents.html
- ComplexSeqVoltages() altdss.types.ComplexArray #
Complex double array of Sequence Voltage for all terminals of active circuit element.
Original COM help: https://opendss.epri.com/CplxSeqVoltages1.html
- Currents() altdss.types.ComplexArray #
Complex array of currents into each conductor of each terminal
Original COM help: https://opendss.epri.com/Currents1.html
- DisplayName: str#
‘property(…)’
Display name of the object (not necessarily unique)
Original COM help: https://opendss.epri.com/DisplayName.html
- EmergAmps: float#
‘property(…)’
Maximum or emerg current.
DSS property name:
EmergAmps
, DSS property index: 11.
- Enabled: bool#
‘property(…)’
{Yes|No or True|False} Indicates whether this element is enabled.
DSS property name:
Enabled
, DSS property index: 16.
- EnergyMeter() Optional[altdss.DSSObj.DSSObj] #
Energy Meter this element is assigned to.
Requires an energy meter with an updated zone.
Original COM help: https://opendss.epri.com/EnergyMeter.html
- EnergyMeterName() str #
Name of the Energy Meter this element is assigned to.
Requires an energy meter with an updated zone.
Original COM help: https://opendss.epri.com/EnergyMeter.html
- FaultRate: float#
‘property(…)’
Failure rate per year.
DSS property name:
FaultRate
, DSS property index: 12.
- FromTerminal() int #
Number of the terminal of this PD element that is on the “from” side.
Requires an energy meter with an updated zone.
- FullName() str #
- GMatrix: altdss.types.Float64Array#
‘property(…)’
Use this to specify a nodal conductance (G) matrix to represent some arbitrary resistance network. Specify in lower triangle form as usual for DSS matrices.
DSS property name:
GMatrix
, DSS property index: 6.
- GUID() str #
Object’s GUID/UUID. Currently used only in the CIM-related methods.
Original COM help: https://opendss.epri.com/GUID.html
- Handle() int #
Index of this element into the circuit’s element list.
Original COM help: https://opendss.epri.com/Handle.html
- HasOCPDevice() bool #
Returns true if a recloser, relay, or fuse controlling the circuit element.
OCP = Overcurrent Protection
Original COM help: https://opendss.epri.com/HasOCPDevice.html
- HasSwitchControl() bool #
Returns true if the element has a SwtControl attached.
Original COM help: https://opendss.epri.com/HasSwitchControl.html
- HasVoltControl() bool #
Returns true if the element has a CapControl or RegControl attached.
Original COM help: https://opendss.epri.com/HasVoltControl.html
- IsIsolated() bool #
Returns true if the element is isolated. Note that this only fetches the current value. See also the Topology interface.
- IsOpen(terminal: int, phase: int) bool #
Returns true if the specified terminal and phase are open.
If the
phase
parameter is zero, returns if any conductor at the terminal is open.
- IsShunt() bool #
Indicates if this PD element should be treated as a shunt element rather than a series element.
Applies to Capacitor, Reactor, Fault and GICTransformer elements.
- Lambda() float #
Failure rate for this branch. Faults per year including length of line.
Requires a previous call to
RelCalc
commandOriginal COM help: https://opendss.epri.com/Lambda1.html
- Like(value: AnyStr)#
Make like another object, e.g.:
New Capacitor.C2 like=c1 …
DSS property name:
Like
, DSS property index: 17.
- Losses() complex #
Total (complex) losses in the element, in VA (watts, vars)
Original COM help: https://opendss.epri.com/Losses1.html
- MaxCurrent(terminal: int) float #
Returns the maximum current (magnitude) at the specified terminal. Use -1 as terminal to get the value across all terminals.
- MinAmps: float#
‘property(…)’
Minimum amps that can sustain a temporary fault. Default is 5.
DSS property name:
MinAmps
, DSS property index: 9.
- property Name: str#
- NodeOrder() altdss.types.Int32Array #
Array of integer containing the node numbers (representing phases, for example) for each conductor of each terminal.
Be sure to run a solution to initialize the values after the circuit is created or modified.
- NodeRef() altdss.types.Int32Array #
Array of integers, a copy of the internal NodeRef of the CktElement.
Be sure to run a solution to initialize the values after the circuit is created or modified.
- NormAmps: float#
‘property(…)’
Normal rated current.
DSS property name:
NormAmps
, DSS property index: 10.
- NumConductors() int #
Number of conductors per terminal
Original COM help: https://opendss.epri.com/NumConductors.html
- NumControllers() int #
Number of controllers connected to this device.
Original COM help: https://opendss.epri.com/NumControls.html
- NumCustomers() int #
Number of customers, this branch.
Requires an energy meter with an updated zone.
Original COM help: https://opendss.epri.com/Numcustomers.html
- NumPhases() int #
Number of phases
Original COM help: https://opendss.epri.com/NumPhases.html
- NumTerminals() int #
Number of terminals in this circuit element
Original COM help: https://opendss.epri.com/NumTerminals.html
- OCPDevice() Union[altdss.DSSObj.DSSObj, None] #
Returns (as a Python object) the OCP device controlling this element, if any.
- OCPDeviceIndex() int #
Index into controller list of OCP Device controlling this circuit element
Original COM help: https://opendss.epri.com/OCPDevIndex.html
- OCPDeviceType() dss.enums.OCPDevType #
Type of OCP controller device
Original COM help: https://opendss.epri.com/OCPDevType.html
- OnTime: float#
‘property(…)’
Time (sec) at which the fault is established for time varying simulations. Default is 0.0 (on at the beginning of the simulation)
DSS property name:
OnTime
, DSS property index: 7.
- Open(terminal: int, phase: int) None #
Open the specified terminal and phase, if non-zero, or all conductors at the terminal.
Original COM help: https://opendss.epri.com/Open1.html
- ParentPDElement() Optional[altdss.DSSObj.DSSObj] #
Parent PD element of this element, if any.
Requires an energy meter with an updated zone.
- PhaseLosses() altdss.types.ComplexArray #
Complex array of losses (kVA) by phase
Original COM help: https://opendss.epri.com/PhaseLosses.html
- Phases: int#
‘property(…)’
Number of Phases. Default is 1.
DSS property name:
Phases
, DSS property index: 3.
- Powers() altdss.types.ComplexArray #
Complex array of powers (kVA) into each conductor of each terminal
Original COM help: https://opendss.epri.com/Powers.html
- R: float#
‘property(…)’
Resistance, each phase, ohms. Default is 0.0001. Assumed to be Mean value if gaussian random mode.Max value if uniform mode. A Fault is actually a series resistance that defaults to a wye connection to ground on the second terminal. You may reconnect the 2nd terminal to achieve whatever connection. Use the Gmatrix property to specify an arbitrary conductance matrix.
DSS property name:
R
, DSS property index: 4.
- Repair: float#
‘property(…)’
Hours to repair.
DSS property name:
Repair
, DSS property index: 14.
- Residuals() altdss.types.Float64Array #
Residual currents for each terminal: (magnitude, angle in degrees)
Original COM help: https://opendss.epri.com/Residuals.html
- SectionID() int #
Integer ID of the feeder section that this PDElement branch is part of.
Requires a previous call to
RelCalc
commandOriginal COM help: https://opendss.epri.com/SectionID1.html
- SeqCurrents() altdss.types.Float64Array #
Array of symmetrical component currents (magnitudes only) into each 3-phase terminal
Original COM help: https://opendss.epri.com/SeqCurrents.html
- SeqPowers() altdss.types.ComplexArray #
Complex array of sequence powers (kW, kvar) into each 3-phase terminal
Original COM help: https://opendss.epri.com/SeqPowers.html
- SeqVoltages() altdss.types.Float64Array #
Double array of symmetrical component voltages (magnitudes only) at each 3-phase terminal
Original COM help: https://opendss.epri.com/SeqVoltages1.html
- Temporary: bool#
‘property(…)’
{Yes | No} Default is No. Designate whether the fault is temporary. For Time-varying simulations, the fault will be removed if the current through the fault drops below the MINAMPS criteria.
DSS property name:
Temporary
, DSS property index: 8.
- TotalCustomers() int #
Total number of customers from this branch to the end of the zone
Requires a circuit with an energy meter with an updated zone.
Original COM help: https://opendss.epri.com/TotalCustomers1.html
- TotalKilometers() float #
Total kilometers of line from this element to the end of the zone. For recloser siting algorithm.
Requires a previous call to
RelCalc
command
- TotalMiles() float #
Total miles of line from this element to the end of the zone. For recloser siting algorithm.
Requires a previous call to
RelCalc
commandOriginal COM help: https://opendss.epri.com/TotalMiles1.html
- TotalPowers() altdss.types.ComplexArray #
Returns an array with the total powers (complex, kVA) at ALL terminals of the active circuit element.
Original COM help: https://opendss.epri.com/TotalPowers.html
- Voltages() altdss.types.ComplexArray #
Complex array of voltages at terminals
Original COM help: https://opendss.epri.com/Voltages1.html
- VoltagesMagAng() altdss.types.Float64Array #
Voltages at each conductor in magnitude, angle form as array of doubles.
Original COM help: https://opendss.epri.com/VoltagesMagAng.html
- YPrim() altdss.types.ComplexArray #
YPrim matrix, column order, complex numbers
Original COM help: https://opendss.epri.com/Yprim.html
- __hash__()#
Return hash(self).
- __init__(api_util, ptr)#
- __ne__(other)#
Return self!=value.
- __repr__()#
Return repr(self).
- begin_edit() None #
Marks a DSS object for editing
In the editing mode, some final side-effects of changing properties are postponed until
end_edit
is called. This side-effects can be somewhat costly, like updating the model parameters or internal matrices.If you don’t have any performance constraint, you may edit each property individually without worrying about using
begin_edit
andend_edit
. For convenience, those are emitted automatically when editing single properties outside an edit block.
- edit(**kwargs: typing_extensions.Unpack[altdss.Fault.FaultProperties]) altdss.Fault.Fault #
Edit this Fault.
This method will try to open a new edit context (if not already open), edit the properties, and finalize the edit context. It can be seen as a shortcut to manually setting each property, or a Pythonic analogous (but extended) to the DSS
Edit
command.- Parameters:
**kwargs – Pass keyword arguments equivalent to the DSS properties of the object.
- Returns:
Returns itself to allow call chaining.
- end_edit(num_changes: int = 1) None #
Leaves the editing state of a DSS object
num_changes
is required for a few classes to correctly match the official OpenDSS behavior and must be the number of properties modified in the current editing block. As of DSS C-API v0.13, this is only required for the Monitor class, when theAction
property is used with theProcess
value.
- pctEmergency(allNodes=False) float #
Maximum current across the conductors as a percentage of the emergency ampere rating.
By default, only the nodes from the first terminal is used for the maximum current, matching the behavior of the “export capacity” command. Pass
allNodes=True
to force the analysis to all terminals.See also: https://sourceforge.net/p/electricdss/discussion/beginners/thread/da5b93ca/
- pctNormal(allNodes=False) float #
Maximum current across the conductors as a percentage of the normal ampere rating.
By default, only the nodes from the first terminal is used for the maximum current, matching the behavior of the “export capacity” command. Pass
allNodes=True
to force the analysis to all terminals.See also: https://sourceforge.net/p/electricdss/discussion/beginners/thread/da5b93ca/
- pctPerm: float#
‘property(…)’
Percent of failures that become permanent.
DSS property name:
pctPerm
, DSS property index: 13.
- pctStdDev: float#
‘property(…)’
Percent standard deviation in resistance to assume for Monte Carlo fault (MF) solution mode for GAUSSIAN distribution. Default is 0 (no variation from mean).
DSS property name:
%StdDev
, DSS property index: 5.
- to_json(options: Union[int, dss.enums.DSSJSONFlags] = 0)#
Returns an element’s data as a JSON-encoded string.
The
options
parameter contains bit-flags to toggle specific features.By default (
options = 0
), only the properties explicitly set. The properties are returned in the order they are set in the input. As a reminder, OpenDSS is sensitive to the order of the properties.The
options
bit-flags are available in theDSSJSONFlags
enum. Values used by this function are:Full
: if set, all properties are returned, ordered by property index instead.SkipRedundant
: if used withFull
, all properties except redundant and unused ones are returned.EnumAsInt
: enumerated properties are returned as integer values instead of strings.FullNames
: any element reference will use the full name ({class name}.{element name}
) even if not required.Pretty
: more whitespace is used in the output for a “prettier” format.SkipDSSClass
: do not add the “DSSClass” property to the JSON objects.
NOT IMPLEMENTED YET:
State
: include run-time state informationDebug
: include debug information
Other bit-flags are reserved for future uses. Please use
DSSJSONFlags
enum to avoid potential conflicts.(API Extension)
- class altdss.Fault.FaultBatch(api_util, **kwargs)#
Bases:
altdss.Batch.DSSBatch
,altdss.CircuitElement.CircuitElementBatchMixin
,altdss.PDElement.PDElementBatchMixin
- AccumulatedL() altdss.types.Float64Array #
Accumulated failure rate for the branch on downline, for each branch in this batch.
Requires a previous call to
RelCalc
commandOriginal COM help: https://opendss.epri.com/AccumulatedL.html
- BaseFreq: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Base Frequency for ratings.
DSS property name:
BaseFreq
, DSS property index: 15.
- Bus1: List[str]#
‘property(…)’
Name of first bus. Examples:
bus1=busname bus1=busname.1.2.3
Bus2 automatically defaults to busname.0,0,0 unless it was previously defined.
DSS property name:
Bus1
, DSS property index: 1.
- Bus2: List[str]#
‘property(…)’
Name of 2nd bus of the 2-terminal Fault object. Defaults to all phases connected to first bus, node 0, if not specified. (Shunt Wye Connection to ground reference)
That is, the Fault defaults to a ground fault unless otherwise specified.
DSS property name:
Bus2
, DSS property index: 2.
- ComplexSeqCurrents() altdss.types.ComplexArray #
Complex double array of Sequence Currents for all conductors of all terminals of active circuit element.
Original COM help: https://opendss.epri.com/CplxSeqCurrents.html
- ComplexSeqVoltages() altdss.types.ComplexArray #
Complex double array of Sequence Voltage for all terminals of active circuit element.
Original COM help: https://opendss.epri.com/CplxSeqVoltages1.html
- Currents() altdss.types.ComplexArray #
Complex array of currents into each conductor of each terminal
Original COM help: https://opendss.epri.com/Currents1.html
- CurrentsMagAng() altdss.types.Float64Array #
Currents in magnitude, angle (degrees) format as a array of doubles.
Original COM help: https://opendss.epri.com/CurrentsMagAng.html
- EmergAmps: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Maximum or emerg current.
DSS property name:
EmergAmps
, DSS property index: 11.
- Enabled: List[bool]#
‘property(…)’
{Yes|No or True|False} Indicates whether this element is enabled.
DSS property name:
Enabled
, DSS property index: 16.
- EnergyMeter() List[Optional[altdss.DSSObj.DSSObj]] #
Return the energy meter for each of the elements in this batch.
Requires an energy meter with an updated zone.
- EnergyMeterName() List[str] #
Return the energy meter name for each of the elements in this batch.
Requires an energy meter with an updated zone.
- FaultRate: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Failure rate per year.
DSS property name:
FaultRate
, DSS property index: 12.
- FromTerminal() altdss.types.Int32Array #
Number of the terminal of each PD element of this batch that is on the “from” side.
Requires an energy meter with an updated zone.
- FullName() List[str] #
Returns the full name (including object type) for all objects in this batch
- GMatrix: List[altdss.types.Float64Array]#
‘property(…)’
Use this to specify a nodal conductance (G) matrix to represent some arbitrary resistance network. Specify in lower triangle form as usual for DSS matrices.
DSS property name:
GMatrix
, DSS property index: 6.
- GUID() List[str] #
GUID/UUID for each object. Currently used only in the CIM-related methods.
Original COM help: https://opendss.epri.com/GUID.html
- Handle() altdss.types.Int32Array #
Index of each element into the circuit’s element list.
Original COM help: https://opendss.epri.com/Handle.html
- HasOCPDevice() altdss.types.BoolArray #
For each element in the batch: returns true if a recloser, relay, or fuse controlling the circuit element.
OCP = Overcurrent Protection
Original COM help: https://opendss.epri.com/HasOCPDevice.html
- HasSwitchControl() altdss.types.BoolArray #
For each element in the batch: returns true if the element has a SwtControl attached.
Original COM help: https://opendss.epri.com/HasSwitchControl.html
- HasVoltControl() altdss.types.BoolArray #
For each element in the batch: returns true if the element has a CapControl or RegControl attached.
Original COM help: https://opendss.epri.com/HasVoltControl.html
- IsIsolated() altdss.types.BoolArray #
For each element in the batch: returns true if the element is isolated. Note that this only fetches the current value. See also the Topology interface.
- IsShunt() List[bool] #
Indicates if each of the PD elements in the batch should be treated as a shunt element rather than a series element.
Applies to Capacitor, Reactor, Fault and GICTransformer elements.
- Lambda() altdss.types.Float64Array #
Failure rate for each of the branches in the batch. Faults per year including length of line.
Requires a previous call to
RelCalc
commandOriginal COM help: https://opendss.epri.com/Lambda1.html
- Like(value: AnyStr, flags: altdss.enums.SetterFlags = 0)#
Make like another object, e.g.:
New Capacitor.C2 like=c1 …
DSS property name:
Like
, DSS property index: 17.
- Losses() altdss.types.ComplexArray #
For each element in the batch: total losses in the element, in VA (watts, vars).
Original COM help: https://opendss.epri.com/Losses1.html
- MaxCurrent(terminal: int) altdss.types.Float64Array #
Returns the maximum current (magnitude) at the specified terminal for each element in this batch. Use -1 as terminal to get the value across all terminals.
- MinAmps: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Minimum amps that can sustain a temporary fault. Default is 5.
DSS property name:
MinAmps
, DSS property index: 9.
- property Name: List[str]#
- NormAmps: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Normal rated current.
DSS property name:
NormAmps
, DSS property index: 10.
- NumConductors() altdss.types.Int32Array #
Number of conductors per terminal for each element in the batch.
Original COM help: https://opendss.epri.com/NumConductors.html
- NumControllers() altdss.types.Int32Array #
Number of controllers connected to each device in the batch.
Original COM help: https://opendss.epri.com/NumControls.html
- NumCustomers() altdss.types.Int32Array #
Number of customers for each branch in the batch.
Requires an energy meter with an updated zone.
Original COM help: https://opendss.epri.com/Numcustomers.html
- NumPhases() altdss.types.Int32Array #
Number of Phases for each element in this batch.
Original COM help: https://opendss.epri.com/NumPhases.html
- NumTerminals() altdss.types.Int32Array #
Number of terminals for each Circuit Element in the batch.
Original COM help: https://opendss.epri.com/NumTerminals.html
- OCPDevice() List[Union[altdss.DSSObj.DSSObj, None]] #
Returns (as a list of Python objects) the OCP device controlling each element.
- OCPDeviceIndex() altdss.types.Int32Array #
For each element in the batch: index into each controller list of the OCP Device controlling each circuit element
Original COM help: https://opendss.epri.com/OCPDevIndex.html
- OCPDeviceType() List[dss.enums.OCPDevType] #
For each element in the batch: type of OCP controller device
Original COM help: https://opendss.epri.com/OCPDevType.html
- OnTime: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Time (sec) at which the fault is established for time varying simulations. Default is 0.0 (on at the beginning of the simulation)
DSS property name:
OnTime
, DSS property index: 7.
- ParentPDElement() List[Optional[altdss.DSSObj.DSSObj]] #
Returns the parent PD element for each element in this batch.
Requires an energy meter with an updated zone.
- PhaseLosses() altdss.types.ComplexArray #
Complex array of losses (kVA) by phase
Original COM help: https://opendss.epri.com/PhaseLosses.html
- Phases: altdss.ArrayProxy.BatchInt32ArrayProxy#
‘property(…)’
Number of Phases. Default is 1.
DSS property name:
Phases
, DSS property index: 3.
- Powers() altdss.types.ComplexArray #
Complex array of powers (kVA) into each conductor of each terminal, of each element in the batch.
Original COM help: https://opendss.epri.com/Powers.html
- R: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Resistance, each phase, ohms. Default is 0.0001. Assumed to be Mean value if gaussian random mode.Max value if uniform mode. A Fault is actually a series resistance that defaults to a wye connection to ground on the second terminal. You may reconnect the 2nd terminal to achieve whatever connection. Use the Gmatrix property to specify an arbitrary conductance matrix.
DSS property name:
R
, DSS property index: 4.
- Repair: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Hours to repair.
DSS property name:
Repair
, DSS property index: 14.
- SectionID() altdss.types.Int32Array #
Integer ID of the feeder section that each PDElement branch in this batch is part of.
Requires a previous call to
RelCalc
commandOriginal COM help: https://opendss.epri.com/SectionID1.html
- SeqCurrents() altdss.types.Float64Array #
Array of symmetrical component currents (magnitudes only) into each 3-phase terminal of each element
Original COM help: https://opendss.epri.com/SeqCurrents.html
- SeqPowers() altdss.types.ComplexArray #
Complex array of sequence powers (kW, kvar) into each 3-phase terminal of each element
Original COM help: https://opendss.epri.com/SeqPowers.html
- SeqVoltages() altdss.types.Float64Array #
Double array of symmetrical component voltages (magnitudes only) at each 3-phase terminal
Original COM help: https://opendss.epri.com/SeqVoltages1.html
- Temporary: List[bool]#
‘property(…)’
{Yes | No} Default is No. Designate whether the fault is temporary. For Time-varying simulations, the fault will be removed if the current through the fault drops below the MINAMPS criteria.
DSS property name:
Temporary
, DSS property index: 8.
- TotalCustomers() altdss.types.Int32Array #
Total number of customers from each branch of this batch to the end of the zone
Requires a circuit with an energy meter with an updated zone.
Original COM help: https://opendss.epri.com/TotalCustomers1.html
- TotalKilometers() altdss.types.Float64Array #
Total kilometers of line from this element to the end of the zone. For recloser siting algorithm.
Requires a previous call to
RelCalc
commandOriginal COM help: https://opendss.epri.com/TotalMiles1.html
- TotalMiles() altdss.types.Float64Array #
Total miles of line from this element to the end of the zone. For recloser siting algorithm.
Requires a previous call to
RelCalc
commandOriginal COM help: https://opendss.epri.com/TotalMiles1.html
- TotalPowers() altdss.types.ComplexArray #
Returns an array with the total powers (complex, kVA) at all terminals of the circuit elements in this batch.
The resulting array is equivalent to concatenating the TotalPowers for each element.
- Voltages() altdss.types.ComplexArray #
Complex array of voltages at terminals
Original COM help: https://opendss.epri.com/Voltages1.html
- VoltagesMagAng() altdss.types.Float64Array #
Voltages at each conductor in magnitude, angle form as array of doubles.
Original COM help: https://opendss.epri.com/VoltagesMagAng.html
- __call__()#
- __getitem__(idx0) altdss.DSSObj.DSSObj #
Get element at 0-based index of the batch pointer array
- __init__(api_util, **kwargs)#
- __iter__()#
- __len__() int #
- batch(**kwargs) altdss.Batch.DSSBatch #
Filter a batch using integer or float DSS properties, returning a new batch.
For integers, provide a single value to match.
For floats, provide a range as a 2-valued tuple/list (min value, max value), or an exact value to value (not recommended).
Multiple properties can be listed to allow filtering various conditions.
Example for loads:
# Create an initial batch using a regular expression abc_loads = altdss.Load.batch(re=r'^abc.*$') # a batch of all loads with names starting with "abc" abc_loads_filtered = abc_loads.batch(Class=1, Phases=1, kV=(0.1, 1.0)) # Create an initial batch, already filtered abc_loads_filtered = altdss.Load.batch(re=r'^abc.*$', Class=1, Phases=1, kV=(0.1, 1.0))
- begin_edit() None #
Marks for editing all DSS objects in the batch
In the editing mode, some final side-effects of changing properties are postponed until
end_edit
is called. This side-effects can be somewhat costly, like updating the model parameters or internal matrices.If you don’t have any performance constraint, you may edit each property individually without worrying about using
begin_edit
andend_edit
. For convenience, those are emitted automatically when editing single properties outside an edit block.
- edit(**kwargs: typing_extensions.Unpack[altdss.Fault.FaultBatchProperties]) altdss.Fault.FaultBatch #
Edit this Fault batch.
This method will try to open a new edit context (if not already open), edit the properties, and finalize the edit context for objects in the batch. It can be seen as a shortcut to manually setting each property, or a Pythonic analogous (but extended) to the DSS
BatchEdit
command.- Parameters:
**kwargs – Pass keyword arguments equivalent to the DSS properties of the objects.
- Returns:
Returns itself to allow call chaining.
- end_edit(num_changes: int = 1) None #
Leaves the editing states of all DSS objects in the batch
num_changes
is required for a few classes to correctly match the official OpenDSS behavior and must be the number of properties modified in the current editing block. As of DSS C-API v0.13, this is only required for the Monitor class, when theAction
property is used with theProcess
value.
- pctEmergency(allNodes=False) altdss.types.Float64Array #
For each element in the batch, calculate the maximum current across the conductors as a percentage of the emergency ampere rating.
By default, only the nodes from the first terminal is used for the maximum current, matching the behavior of the “export capacity” command. Pass
allNodes=True
to force the analysis to all terminals.See also: https://sourceforge.net/p/electricdss/discussion/beginners/thread/da5b93ca/
- pctNormal(allNodes=False) altdss.types.Float64Array #
For each element in the batch, calculate the maximum current across the conductors as a percentage of the normal ampere rating.
By default, only the nodes from the first terminal is used for the maximum current, matching the behavior of the “export capacity” command. Pass
allNodes=True
to force the analysis to all terminals.See also: https://sourceforge.net/p/electricdss/discussion/beginners/thread/da5b93ca/
- pctPerm: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Percent of failures that become permanent.
DSS property name:
pctPerm
, DSS property index: 13.
- pctStdDev: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Percent standard deviation in resistance to assume for Monte Carlo fault (MF) solution mode for GAUSSIAN distribution. Default is 0 (no variation from mean).
DSS property name:
%StdDev
, DSS property index: 5.
- to_json(options: Union[int, dss.enums.DSSJSONFlags] = 0)#
Returns the data (as a list) of the elements in a batch as a JSON-encoded string.
The
options
parameter contains bit-flags to toggle specific features. SeeObj_ToJSON
(C-API) for more, orDSSObj.to_json
in Python.Additionally, the
ExcludeDisabled
flag can be used to excluded disabled elements from the output.
- to_list()#
- class altdss.Fault.FaultBatchProperties#
Bases:
typing_extensions.TypedDict
dict() -> new empty dictionary dict(mapping) -> new dictionary initialized from a mapping object’s (key, value) pairs dict(iterable) -> new dictionary initialized as if via: d = {} for k, v in iterable: d[k] = v dict(**kwargs) -> new dictionary initialized with the name=value pairs in the keyword argument list. For example: dict(one=1, two=2)
- BaseFreq: Union[float, altdss.types.Float64Array]#
None
- Bus1: Union[AnyStr, List[AnyStr]]#
None
- Bus2: Union[AnyStr, List[AnyStr]]#
None
- EmergAmps: Union[float, altdss.types.Float64Array]#
None
- Enabled: bool#
None
- FaultRate: Union[float, altdss.types.Float64Array]#
None
- GMatrix: altdss.types.Float64Array#
None
- Like: AnyStr#
None
- MinAmps: Union[float, altdss.types.Float64Array]#
None
- NormAmps: Union[float, altdss.types.Float64Array]#
None
- OnTime: Union[float, altdss.types.Float64Array]#
None
- Phases: Union[int, altdss.types.Int32Array]#
None
- R: Union[float, altdss.types.Float64Array]#
None
- Repair: Union[float, altdss.types.Float64Array]#
None
- Temporary: bool#
None
- __contains__()#
True if the dictionary has the specified key, else False.
- __delattr__()#
Implement delattr(self, name).
- __delitem__()#
Delete self[key].
- __dir__()#
Default dir() implementation.
- __format__()#
Default object formatter.
Return str(self) if format_spec is empty. Raise TypeError otherwise.
- __ge__()#
Return self>=value.
- __getattribute__()#
Return getattr(self, name).
- __getitem__()#
Return self[key].
- __getstate__()#
Helper for pickle.
- __gt__()#
Return self>value.
- __init__()#
Initialize self. See help(type(self)) for accurate signature.
- __ior__()#
Return self|=value.
- __iter__()#
Implement iter(self).
- __le__()#
Return self<=value.
- __len__()#
Return len(self).
- __lt__()#
Return self<value.
- __ne__()#
Return self!=value.
- __new__()#
Create and return a new object. See help(type) for accurate signature.
- __or__()#
Return self|value.
- __reduce__()#
Helper for pickle.
- __reduce_ex__()#
Helper for pickle.
- __repr__()#
Return repr(self).
- __reversed__()#
Return a reverse iterator over the dict keys.
- __ror__()#
Return value|self.
- __setitem__()#
Set self[key] to value.
- __sizeof__()#
D.sizeof() -> size of D in memory, in bytes
- __str__()#
Return str(self).
- __subclasshook__()#
Abstract classes can override this to customize issubclass().
This is invoked early on by abc.ABCMeta.subclasscheck(). It should return True, False or NotImplemented. If it returns NotImplemented, the normal algorithm is used. Otherwise, it overrides the normal algorithm (and the outcome is cached).
- clear()#
D.clear() -> None. Remove all items from D.
- copy()#
D.copy() -> a shallow copy of D
- get()#
Return the value for key if key is in the dictionary, else default.
- items()#
D.items() -> a set-like object providing a view on D’s items
- keys()#
D.keys() -> a set-like object providing a view on D’s keys
- pctPerm: Union[float, altdss.types.Float64Array]#
None
- pctStdDev: Union[float, altdss.types.Float64Array]#
None
- pop()#
D.pop(k[,d]) -> v, remove specified key and return the corresponding value.
If the key is not found, return the default if given; otherwise, raise a KeyError.
- popitem()#
Remove and return a (key, value) pair as a 2-tuple.
Pairs are returned in LIFO (last-in, first-out) order. Raises KeyError if the dict is empty.
- setdefault()#
Insert key with a value of default if key is not in the dictionary.
Return the value for key if key is in the dictionary, else default.
- update()#
D.update([E, ]**F) -> None. Update D from dict/iterable E and F. If E is present and has a .keys() method, then does: for k in E: D[k] = E[k] If E is present and lacks a .keys() method, then does: for k, v in E: D[k] = v In either case, this is followed by: for k in F: D[k] = F[k]
- values()#
D.values() -> an object providing a view on D’s values
- class altdss.Fault.FaultProperties#
Bases:
typing_extensions.TypedDict
dict() -> new empty dictionary dict(mapping) -> new dictionary initialized from a mapping object’s (key, value) pairs dict(iterable) -> new dictionary initialized as if via: d = {} for k, v in iterable: d[k] = v dict(**kwargs) -> new dictionary initialized with the name=value pairs in the keyword argument list. For example: dict(one=1, two=2)
- BaseFreq: float#
None
- Bus1: AnyStr#
None
- Bus2: AnyStr#
None
- EmergAmps: float#
None
- Enabled: bool#
None
- FaultRate: float#
None
- GMatrix: altdss.types.Float64Array#
None
- Like: AnyStr#
None
- MinAmps: float#
None
- NormAmps: float#
None
- OnTime: float#
None
- Phases: int#
None
- R: float#
None
- Repair: float#
None
- Temporary: bool#
None
- __contains__()#
True if the dictionary has the specified key, else False.
- __delattr__()#
Implement delattr(self, name).
- __delitem__()#
Delete self[key].
- __dir__()#
Default dir() implementation.
- __format__()#
Default object formatter.
Return str(self) if format_spec is empty. Raise TypeError otherwise.
- __ge__()#
Return self>=value.
- __getattribute__()#
Return getattr(self, name).
- __getitem__()#
Return self[key].
- __getstate__()#
Helper for pickle.
- __gt__()#
Return self>value.
- __init__()#
Initialize self. See help(type(self)) for accurate signature.
- __ior__()#
Return self|=value.
- __iter__()#
Implement iter(self).
- __le__()#
Return self<=value.
- __len__()#
Return len(self).
- __lt__()#
Return self<value.
- __ne__()#
Return self!=value.
- __new__()#
Create and return a new object. See help(type) for accurate signature.
- __or__()#
Return self|value.
- __reduce__()#
Helper for pickle.
- __reduce_ex__()#
Helper for pickle.
- __repr__()#
Return repr(self).
- __reversed__()#
Return a reverse iterator over the dict keys.
- __ror__()#
Return value|self.
- __setitem__()#
Set self[key] to value.
- __sizeof__()#
D.sizeof() -> size of D in memory, in bytes
- __str__()#
Return str(self).
- __subclasshook__()#
Abstract classes can override this to customize issubclass().
This is invoked early on by abc.ABCMeta.subclasscheck(). It should return True, False or NotImplemented. If it returns NotImplemented, the normal algorithm is used. Otherwise, it overrides the normal algorithm (and the outcome is cached).
- clear()#
D.clear() -> None. Remove all items from D.
- copy()#
D.copy() -> a shallow copy of D
- get()#
Return the value for key if key is in the dictionary, else default.
- items()#
D.items() -> a set-like object providing a view on D’s items
- keys()#
D.keys() -> a set-like object providing a view on D’s keys
- pctPerm: float#
None
- pctStdDev: float#
None
- pop()#
D.pop(k[,d]) -> v, remove specified key and return the corresponding value.
If the key is not found, return the default if given; otherwise, raise a KeyError.
- popitem()#
Remove and return a (key, value) pair as a 2-tuple.
Pairs are returned in LIFO (last-in, first-out) order. Raises KeyError if the dict is empty.
- setdefault()#
Insert key with a value of default if key is not in the dictionary.
Return the value for key if key is in the dictionary, else default.
- update()#
D.update([E, ]**F) -> None. Update D from dict/iterable E and F. If E is present and has a .keys() method, then does: for k in E: D[k] = E[k] If E is present and lacks a .keys() method, then does: for k, v in E: D[k] = v In either case, this is followed by: for k in F: D[k] = F[k]
- values()#
D.values() -> an object providing a view on D’s values
- class altdss.Fault.IFault(iobj)#
Bases:
altdss.DSSObj.IDSSObj
,altdss.Fault.FaultBatch
- AccumulatedL() altdss.types.Float64Array #
Accumulated failure rate for the branch on downline, for each branch in this batch.
Requires a previous call to
RelCalc
commandOriginal COM help: https://opendss.epri.com/AccumulatedL.html
- BaseFreq: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Base Frequency for ratings.
DSS property name:
BaseFreq
, DSS property index: 15.
- Bus1: List[str]#
‘property(…)’
Name of first bus. Examples:
bus1=busname bus1=busname.1.2.3
Bus2 automatically defaults to busname.0,0,0 unless it was previously defined.
DSS property name:
Bus1
, DSS property index: 1.
- Bus2: List[str]#
‘property(…)’
Name of 2nd bus of the 2-terminal Fault object. Defaults to all phases connected to first bus, node 0, if not specified. (Shunt Wye Connection to ground reference)
That is, the Fault defaults to a ground fault unless otherwise specified.
DSS property name:
Bus2
, DSS property index: 2.
- ComplexSeqCurrents() altdss.types.ComplexArray #
Complex double array of Sequence Currents for all conductors of all terminals of active circuit element.
Original COM help: https://opendss.epri.com/CplxSeqCurrents.html
- ComplexSeqVoltages() altdss.types.ComplexArray #
Complex double array of Sequence Voltage for all terminals of active circuit element.
Original COM help: https://opendss.epri.com/CplxSeqVoltages1.html
- Currents() altdss.types.ComplexArray #
Complex array of currents into each conductor of each terminal
Original COM help: https://opendss.epri.com/Currents1.html
- CurrentsMagAng() altdss.types.Float64Array #
Currents in magnitude, angle (degrees) format as a array of doubles.
Original COM help: https://opendss.epri.com/CurrentsMagAng.html
- EmergAmps: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Maximum or emerg current.
DSS property name:
EmergAmps
, DSS property index: 11.
- Enabled: List[bool]#
‘property(…)’
{Yes|No or True|False} Indicates whether this element is enabled.
DSS property name:
Enabled
, DSS property index: 16.
- EnergyMeter() List[Optional[altdss.DSSObj.DSSObj]] #
Return the energy meter for each of the elements in this batch.
Requires an energy meter with an updated zone.
- EnergyMeterName() List[str] #
Return the energy meter name for each of the elements in this batch.
Requires an energy meter with an updated zone.
- FaultRate: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Failure rate per year.
DSS property name:
FaultRate
, DSS property index: 12.
- FromTerminal() altdss.types.Int32Array #
Number of the terminal of each PD element of this batch that is on the “from” side.
Requires an energy meter with an updated zone.
- FullName() List[str] #
Returns the full name (including object type) for all objects in this batch
- GMatrix: List[altdss.types.Float64Array]#
‘property(…)’
Use this to specify a nodal conductance (G) matrix to represent some arbitrary resistance network. Specify in lower triangle form as usual for DSS matrices.
DSS property name:
GMatrix
, DSS property index: 6.
- GUID() List[str] #
GUID/UUID for each object. Currently used only in the CIM-related methods.
Original COM help: https://opendss.epri.com/GUID.html
- Handle() altdss.types.Int32Array #
Index of each element into the circuit’s element list.
Original COM help: https://opendss.epri.com/Handle.html
- HasOCPDevice() altdss.types.BoolArray #
For each element in the batch: returns true if a recloser, relay, or fuse controlling the circuit element.
OCP = Overcurrent Protection
Original COM help: https://opendss.epri.com/HasOCPDevice.html
- HasSwitchControl() altdss.types.BoolArray #
For each element in the batch: returns true if the element has a SwtControl attached.
Original COM help: https://opendss.epri.com/HasSwitchControl.html
- HasVoltControl() altdss.types.BoolArray #
For each element in the batch: returns true if the element has a CapControl or RegControl attached.
Original COM help: https://opendss.epri.com/HasVoltControl.html
- IsIsolated() altdss.types.BoolArray #
For each element in the batch: returns true if the element is isolated. Note that this only fetches the current value. See also the Topology interface.
- IsShunt() List[bool] #
Indicates if each of the PD elements in the batch should be treated as a shunt element rather than a series element.
Applies to Capacitor, Reactor, Fault and GICTransformer elements.
- Lambda() altdss.types.Float64Array #
Failure rate for each of the branches in the batch. Faults per year including length of line.
Requires a previous call to
RelCalc
commandOriginal COM help: https://opendss.epri.com/Lambda1.html
- Like(value: AnyStr, flags: altdss.enums.SetterFlags = 0)#
Make like another object, e.g.:
New Capacitor.C2 like=c1 …
DSS property name:
Like
, DSS property index: 17.
- Losses() altdss.types.ComplexArray #
For each element in the batch: total losses in the element, in VA (watts, vars).
Original COM help: https://opendss.epri.com/Losses1.html
- MaxCurrent(terminal: int) altdss.types.Float64Array #
Returns the maximum current (magnitude) at the specified terminal for each element in this batch. Use -1 as terminal to get the value across all terminals.
- MinAmps: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Minimum amps that can sustain a temporary fault. Default is 5.
DSS property name:
MinAmps
, DSS property index: 9.
- property Name: List[str]#
- NormAmps: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Normal rated current.
DSS property name:
NormAmps
, DSS property index: 10.
- NumConductors() altdss.types.Int32Array #
Number of conductors per terminal for each element in the batch.
Original COM help: https://opendss.epri.com/NumConductors.html
- NumControllers() altdss.types.Int32Array #
Number of controllers connected to each device in the batch.
Original COM help: https://opendss.epri.com/NumControls.html
- NumCustomers() altdss.types.Int32Array #
Number of customers for each branch in the batch.
Requires an energy meter with an updated zone.
Original COM help: https://opendss.epri.com/Numcustomers.html
- NumPhases() altdss.types.Int32Array #
Number of Phases for each element in this batch.
Original COM help: https://opendss.epri.com/NumPhases.html
- NumTerminals() altdss.types.Int32Array #
Number of terminals for each Circuit Element in the batch.
Original COM help: https://opendss.epri.com/NumTerminals.html
- OCPDevice() List[Union[altdss.DSSObj.DSSObj, None]] #
Returns (as a list of Python objects) the OCP device controlling each element.
- OCPDeviceIndex() altdss.types.Int32Array #
For each element in the batch: index into each controller list of the OCP Device controlling each circuit element
Original COM help: https://opendss.epri.com/OCPDevIndex.html
- OCPDeviceType() List[dss.enums.OCPDevType] #
For each element in the batch: type of OCP controller device
Original COM help: https://opendss.epri.com/OCPDevType.html
- OnTime: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Time (sec) at which the fault is established for time varying simulations. Default is 0.0 (on at the beginning of the simulation)
DSS property name:
OnTime
, DSS property index: 7.
- ParentPDElement() List[Optional[altdss.DSSObj.DSSObj]] #
Returns the parent PD element for each element in this batch.
Requires an energy meter with an updated zone.
- PhaseLosses() altdss.types.ComplexArray #
Complex array of losses (kVA) by phase
Original COM help: https://opendss.epri.com/PhaseLosses.html
- Phases: altdss.ArrayProxy.BatchInt32ArrayProxy#
‘property(…)’
Number of Phases. Default is 1.
DSS property name:
Phases
, DSS property index: 3.
- Powers() altdss.types.ComplexArray #
Complex array of powers (kVA) into each conductor of each terminal, of each element in the batch.
Original COM help: https://opendss.epri.com/Powers.html
- R: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Resistance, each phase, ohms. Default is 0.0001. Assumed to be Mean value if gaussian random mode.Max value if uniform mode. A Fault is actually a series resistance that defaults to a wye connection to ground on the second terminal. You may reconnect the 2nd terminal to achieve whatever connection. Use the Gmatrix property to specify an arbitrary conductance matrix.
DSS property name:
R
, DSS property index: 4.
- Repair: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Hours to repair.
DSS property name:
Repair
, DSS property index: 14.
- SectionID() altdss.types.Int32Array #
Integer ID of the feeder section that each PDElement branch in this batch is part of.
Requires a previous call to
RelCalc
commandOriginal COM help: https://opendss.epri.com/SectionID1.html
- SeqCurrents() altdss.types.Float64Array #
Array of symmetrical component currents (magnitudes only) into each 3-phase terminal of each element
Original COM help: https://opendss.epri.com/SeqCurrents.html
- SeqPowers() altdss.types.ComplexArray #
Complex array of sequence powers (kW, kvar) into each 3-phase terminal of each element
Original COM help: https://opendss.epri.com/SeqPowers.html
- SeqVoltages() altdss.types.Float64Array #
Double array of symmetrical component voltages (magnitudes only) at each 3-phase terminal
Original COM help: https://opendss.epri.com/SeqVoltages1.html
- Temporary: List[bool]#
‘property(…)’
{Yes | No} Default is No. Designate whether the fault is temporary. For Time-varying simulations, the fault will be removed if the current through the fault drops below the MINAMPS criteria.
DSS property name:
Temporary
, DSS property index: 8.
- TotalCustomers() altdss.types.Int32Array #
Total number of customers from each branch of this batch to the end of the zone
Requires a circuit with an energy meter with an updated zone.
Original COM help: https://opendss.epri.com/TotalCustomers1.html
- TotalKilometers() altdss.types.Float64Array #
Total kilometers of line from this element to the end of the zone. For recloser siting algorithm.
Requires a previous call to
RelCalc
commandOriginal COM help: https://opendss.epri.com/TotalMiles1.html
- TotalMiles() altdss.types.Float64Array #
Total miles of line from this element to the end of the zone. For recloser siting algorithm.
Requires a previous call to
RelCalc
commandOriginal COM help: https://opendss.epri.com/TotalMiles1.html
- TotalPowers() altdss.types.ComplexArray #
Returns an array with the total powers (complex, kVA) at all terminals of the circuit elements in this batch.
The resulting array is equivalent to concatenating the TotalPowers for each element.
- Voltages() altdss.types.ComplexArray #
Complex array of voltages at terminals
Original COM help: https://opendss.epri.com/Voltages1.html
- VoltagesMagAng() altdss.types.Float64Array #
Voltages at each conductor in magnitude, angle form as array of doubles.
Original COM help: https://opendss.epri.com/VoltagesMagAng.html
- __call__()#
- __contains__(name: str) bool #
- __getitem__(name_or_idx)#
- __init__(iobj)#
- __iter__()#
- __len__() int #
- batch(**kwargs)#
Creates a new batch handler of (existing) objects
- batch_new(names: Optional[List[AnyStr]] = None, *, df=None, count: Optional[int] = None, begin_edit: Optional[bool] = None, **kwargs: typing_extensions.Unpack[altdss.Fault.FaultBatchProperties]) altdss.Fault.FaultBatch #
Creates a new batch of Fault objects
Either
names
,count
ordf
is required.- Parameters:
begin_edit – The argument
begin_edit
indicates if the user want to leave the elements in the edit state, and requires a call toend_edit()
or equivalent. The defaultbegin_edit
is set toNone
. WithNone
, the behavior will be adjusted according the default of how the batch is created.**kwargs – Pass keyword arguments equivalent to the DSS properties of the object.
names – When using a list of names, each new object will match the names from this list.
begin_edit
defaults toTrue
if no arguments for properties were passed,False
otherwise.count – When using
count
, new objects will be created with based on a random prefix, with an increasing integer up tocount
.begin_edit
defaults toTrue
if no arguments for properties were passed,False
otherwise.df – Currently EXPERIMENTAL AND LIMITED, tries to get the columns from a dataframe to populate the names and the DSS properties.
begin_edit
defaults toFalse
.
- Returns:
Returns the new batch of DSS objects, wrapped in Python.
Note that, to make it easier for new users where the edit context might not be too relevant, AltDSS automatically opens/closes edit contexts for single properties if the object is not in the edit state already.
- begin_edit() None #
Marks for editing all DSS objects in the batch
In the editing mode, some final side-effects of changing properties are postponed until
end_edit
is called. This side-effects can be somewhat costly, like updating the model parameters or internal matrices.If you don’t have any performance constraint, you may edit each property individually without worrying about using
begin_edit
andend_edit
. For convenience, those are emitted automatically when editing single properties outside an edit block.
- edit(**kwargs: typing_extensions.Unpack[altdss.Fault.FaultBatchProperties]) altdss.Fault.FaultBatch #
Edit this Fault batch.
This method will try to open a new edit context (if not already open), edit the properties, and finalize the edit context for objects in the batch. It can be seen as a shortcut to manually setting each property, or a Pythonic analogous (but extended) to the DSS
BatchEdit
command.- Parameters:
**kwargs – Pass keyword arguments equivalent to the DSS properties of the objects.
- Returns:
Returns itself to allow call chaining.
- end_edit(num_changes: int = 1) None #
Leaves the editing states of all DSS objects in the batch
num_changes
is required for a few classes to correctly match the official OpenDSS behavior and must be the number of properties modified in the current editing block. As of DSS C-API v0.13, this is only required for the Monitor class, when theAction
property is used with theProcess
value.
- find(name_or_idx: Union[AnyStr, int]) altdss.DSSObj.DSSObj #
Returns an object from the collection by name or index; the index must be zero-based.
- new(name: AnyStr, *, begin_edit: Optional[bool] = None, activate=False, **kwargs: typing_extensions.Unpack[altdss.Fault.FaultProperties]) altdss.Fault.Fault #
Creates a new Fault.
- Parameters:
name – The object’s name is a required positional argument.
activate – Activation (setting
activate
to true) is useful for integration with the classic API, and some internal OpenDSS commands. If you interact with this object only via the Alt API, no need to activate it (due to performance costs).begin_edit – This controls how the edit context is left after the object creation:
True
: The object will be left in the edit state, requiring anend_edit
call or equivalent.False
: No edit context is started.None
: If no properties are passed as keyword arguments, the object will be left in the edit state (assumes the user will fill the properties from Python attributes). Otherwise, the internal edit context will be finalized.
- Parameters:
**kwargs – Pass keyword arguments equivalent to the DSS properties of the object.
- Returns:
Returns the new DSS object, wrapped in Python.
Note that, to make it easier for new users where the edit context might not be too relevant, AltDSS automatically opens/closes edit contexts for single properties if the object is not in the edit state already.
- pctEmergency(allNodes=False) altdss.types.Float64Array #
For each element in the batch, calculate the maximum current across the conductors as a percentage of the emergency ampere rating.
By default, only the nodes from the first terminal is used for the maximum current, matching the behavior of the “export capacity” command. Pass
allNodes=True
to force the analysis to all terminals.See also: https://sourceforge.net/p/electricdss/discussion/beginners/thread/da5b93ca/
- pctNormal(allNodes=False) altdss.types.Float64Array #
For each element in the batch, calculate the maximum current across the conductors as a percentage of the normal ampere rating.
By default, only the nodes from the first terminal is used for the maximum current, matching the behavior of the “export capacity” command. Pass
allNodes=True
to force the analysis to all terminals.See also: https://sourceforge.net/p/electricdss/discussion/beginners/thread/da5b93ca/
- pctPerm: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Percent of failures that become permanent.
DSS property name:
pctPerm
, DSS property index: 13.
- pctStdDev: altdss.ArrayProxy.BatchFloat64ArrayProxy#
‘property(…)’
Percent standard deviation in resistance to assume for Monte Carlo fault (MF) solution mode for GAUSSIAN distribution. Default is 0 (no variation from mean).
DSS property name:
%StdDev
, DSS property index: 5.
- to_json(options: Union[int, dss.enums.DSSJSONFlags] = 0)#
Returns the data (as a list) of the elements in a batch as a JSON-encoded string.
The
options
parameter contains bit-flags to toggle specific features. SeeObj_ToJSON
(C-API) for more, orDSSObj.to_json
in Python.Additionally, the
ExcludeDisabled
flag can be used to excluded disabled elements from the output.
- to_list()#