altdss.UPFC

Contents

altdss.UPFC#

Module Contents#

Classes#

IUPFC

UPFC

UPFCBatch

UPFCBatchProperties

dict() -> new empty dictionary dict(mapping) -> new dictionary initialized from a mapping object’s (key, value) pairs dict(iterable) -> new dictionary initialized as if via: d = {} for k, v in iterable: d[k] = v dict(**kwargs) -> new dictionary initialized with the name=value pairs in the keyword argument list. For example: dict(one=1, two=2)

UPFCProperties

dict() -> new empty dictionary dict(mapping) -> new dictionary initialized from a mapping object’s (key, value) pairs dict(iterable) -> new dictionary initialized as if via: d = {} for k, v in iterable: d[k] = v dict(**kwargs) -> new dictionary initialized with the name=value pairs in the keyword argument list. For example: dict(one=1, two=2)

Data#

PDElement

API#

class altdss.UPFC.IUPFC(iobj)#

Bases: altdss.DSSObj.IDSSObj, altdss.UPFC.UPFCBatch

BaseFreq: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Base Frequency for ratings.

DSS property name: BaseFreq, DSS property index: 19.

Bus1: List[str]#

‘property(…)’

Name of bus to which the input terminal (1) is connected. bus1=busname.1.3 bus1=busname.1.2.3

DSS property name: Bus1, DSS property index: 1.

Bus2: List[str]#

‘property(…)’

Name of bus to which the output terminal (2) is connected. bus2=busname.1.2 bus2=busname.1.2.3

DSS property name: Bus2, DSS property index: 2.

CLimit: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Current Limit for the UPFC, if the current passing through the UPFC is higher than this value the UPFC turns off. This value is specified in Amps (Default 265 A)

DSS property name: CLimit, DSS property index: 14.

ComplexSeqCurrents() altdss.types.ComplexArray#

Complex double array of Sequence Currents for all conductors of all terminals of active circuit element.

Original COM help: https://opendss.epri.com/CplxSeqCurrents.html

ComplexSeqVoltages() altdss.types.ComplexArray#

Complex double array of Sequence Voltage for all terminals of active circuit element.

Original COM help: https://opendss.epri.com/CplxSeqVoltages1.html

Currents() altdss.types.ComplexArray#

Complex array of currents into each conductor of each terminal

Original COM help: https://opendss.epri.com/Currents1.html

CurrentsMagAng() altdss.types.Float64Array#

Currents in magnitude, angle (degrees) format as a array of doubles.

Original COM help: https://opendss.epri.com/CurrentsMagAng.html

Element: List[altdss.UPFC.PDElement]#

‘property(…)’

The name of the PD element monitored when operating with reactive power compensation. Normally, it should be the PD element immediately upstream the UPFC. The element must be defined including the class, e.g. Line.myline.

DSS property name: Element, DSS property index: 17.

Element_str: List[str]#

‘property(…)’

The name of the PD element monitored when operating with reactive power compensation. Normally, it should be the PD element immediately upstream the UPFC. The element must be defined including the class, e.g. Line.myline.

DSS property name: Element, DSS property index: 17.

Enabled: List[bool]#

‘property(…)’

{Yes|No or True|False} Indicates whether this element is enabled.

DSS property name: Enabled, DSS property index: 20.

EnergyMeter() List[altdss.DSSObj.DSSObj]#
EnergyMeterName() List[str]#
Frequency: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

UPFC working frequency. Defaults to system default base frequency.

DSS property name: Frequency, DSS property index: 5.

FullName() List[str]#

Returns the full name (including object type) for all objects in this batch

GUID() List[str]#

GUID/UUID for each object. Currently used only in the CIM-related methods.

Original COM help: https://opendss.epri.com/GUID.html

Handle() altdss.types.Int32Array#

Index of each element into the circuit’s element list.

Original COM help: https://opendss.epri.com/Handle.html

HasOCPDevice() altdss.types.BoolArray#

For each element in the batch: returns true if a recloser, relay, or fuse controlling the circuit element.

OCP = Overcurrent Protection

Original COM help: https://opendss.epri.com/HasOCPDevice.html

HasSwitchControl() altdss.types.BoolArray#

For each element in the batch: returns true if the element has a SwtControl attached.

Original COM help: https://opendss.epri.com/HasSwitchControl.html

HasVoltControl() altdss.types.BoolArray#

For each element in the batch: returns true if the element has a CapControl or RegControl attached.

Original COM help: https://opendss.epri.com/HasVoltControl.html

IsIsolated() altdss.types.BoolArray#

For each element in the batch: returns true if the element is isolated. Note that this only fetches the current value. See also the Topology interface.

Like(value: AnyStr, flags: altdss.enums.SetterFlags = 0)#

Make like another object, e.g.:

New Capacitor.C2 like=c1 …

DSS property name: Like, DSS property index: 21.

LossCurve: List[altdss.XYcurve.XYcurve]#

‘property(…)’

Name of the XYCurve for describing the losses behavior as a function of the voltage at the input of the UPFC

DSS property name: LossCurve, DSS property index: 11.

LossCurve_str: List[str]#

‘property(…)’

Name of the XYCurve for describing the losses behavior as a function of the voltage at the input of the UPFC

DSS property name: LossCurve, DSS property index: 11.

Losses() altdss.types.ComplexArray#

For each element in the batch: total losses in the element, in VA (watts, vars).

Original COM help: https://opendss.epri.com/Losses1.html

MaxCurrent(terminal: int) altdss.types.Float64Array#

Returns the maximum current (magnitude) at the specified terminal for each element in this batch. Use -1 as terminal to get the value across all terminals.

Mode: altdss.ArrayProxy.BatchInt32ArrayProxy#

‘property(…)’

Integer used to define the control mode of the UPFC:

0 = Off, 1 = Voltage regulator, 2 = Phase angle regulator, 3 = Dual mode 4 = It is a control mode where the user can set two different set points to create a secure GAP, these references must be defined in the parameters RefkV and RefkV2. The only restriction when setting these values is that RefkV must be higher than RefkV2. 5 = In this mode the user can define the same GAP using two set points as in control mode 4. The only difference between mode 5 and mode 4 is that in mode 5, the UPFC controller performs dual control actions just as in control mode 3

DSS property name: Mode, DSS property index: 9.

property Name: List[str]#
NumConductors() altdss.types.Int32Array#

Number of conductors per terminal for each element in the batch.

Original COM help: https://opendss.epri.com/NumConductors.html

NumControllers() altdss.types.Int32Array#

Number of controllers connected to each device in the batch.

Original COM help: https://opendss.epri.com/NumControls.html

NumPhases() altdss.types.Int32Array#

Number of Phases for each element in this batch.

Original COM help: https://opendss.epri.com/NumPhases.html

NumTerminals() altdss.types.Int32Array#

Number of terminals for each Circuit Element in the batch.

Original COM help: https://opendss.epri.com/NumTerminals.html

OCPDevice() List[Union[altdss.DSSObj.DSSObj, None]]#

Returns (as a list of Python objects) the OCP device controlling each element.

OCPDeviceIndex() altdss.types.Int32Array#

For each element in the batch: index into each controller list of the OCP Device controlling each circuit element

Original COM help: https://opendss.epri.com/OCPDevIndex.html

OCPDeviceType() List[dss.enums.OCPDevType]#

For each element in the batch: type of OCP controller device

Original COM help: https://opendss.epri.com/OCPDevType.html

PF: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Power factor target at the input terminal.

DSS property name: PF, DSS property index: 4.

PhaseLosses() altdss.types.ComplexArray#

Complex array of losses (kVA) by phase

Original COM help: https://opendss.epri.com/PhaseLosses.html

Phases: altdss.ArrayProxy.BatchInt32ArrayProxy#

‘property(…)’

Number of phases. Defaults to 1 phase (2 terminals, 1 conductor per terminal).

DSS property name: Phases, DSS property index: 6.

Powers() altdss.types.ComplexArray#

Complex array of powers (kVA) into each conductor of each terminal, of each element in the batch.

Original COM help: https://opendss.epri.com/Powers.html

RefkV: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Base Voltage expected at the output of the UPFC

“refkv=0.24”

DSS property name: RefkV, DSS property index: 3.

SeqCurrents() altdss.types.Float64Array#

Array of symmetrical component currents (magnitudes only) into each 3-phase terminal of each element

Original COM help: https://opendss.epri.com/SeqCurrents.html

SeqPowers() altdss.types.ComplexArray#

Complex array of sequence powers (kW, kvar) into each 3-phase terminal of each element

Original COM help: https://opendss.epri.com/SeqPowers.html

SeqVoltages() altdss.types.Float64Array#

Double array of symmetrical component voltages (magnitudes only) at each 3-phase terminal

Original COM help: https://opendss.epri.com/SeqVoltages1.html

Spectrum: List[altdss.Spectrum.Spectrum]#

‘property(…)’

Name of harmonic spectrum for this source. Default is “defaultUPFC”, which is defined when the DSS starts.

DSS property name: Spectrum, DSS property index: 18.

Spectrum_str: List[str]#

‘property(…)’

Name of harmonic spectrum for this source. Default is “defaultUPFC”, which is defined when the DSS starts.

DSS property name: Spectrum, DSS property index: 18.

Tol1: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Tolerance in pu for the series PI controller Tol1=0.02 is the format used to define 2% tolerance (Default=2%)

DSS property name: Tol1, DSS property index: 8.

TotalPowers() altdss.types.ComplexArray#

Returns an array with the total powers (complex, kVA) at all terminals of the circuit elements in this batch.

The resulting array is equivalent to concatenating the TotalPowers for each element.

VHLimit: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

High limit for the voltage at the input of the UPFC, if the voltage is above this value the UPFC turns off. This value is specified in Volts (default 300 V)

DSS property name: VHLimit, DSS property index: 12.

VLLimit: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

low limit for the voltage at the input of the UPFC, if voltage is below this value the UPFC turns off. This value is specified in Volts (default 125 V)

DSS property name: VLLimit, DSS property index: 13.

Voltages() altdss.types.ComplexArray#

Complex array of voltages at terminals

Original COM help: https://opendss.epri.com/Voltages1.html

VoltagesMagAng() altdss.types.Float64Array#

Voltages at each conductor in magnitude, angle form as array of doubles.

Original COM help: https://opendss.epri.com/VoltagesMagAng.html

VpqMax: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Maximum voltage (in volts) delivered by the series voltage source (Default = 24 V)

DSS property name: VpqMax, DSS property index: 10.

Xs: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Reactance of the series transformer of the UPFC, ohms (default=0.7540 … 2 mH)

DSS property name: Xs, DSS property index: 7.

__call__()#
__contains__(name: str) bool#
__getitem__(name_or_idx)#
__init__(iobj)#
__iter__()#
__len__() int#
batch(**kwargs)#

Creates a new batch handler of (existing) objects

batch_new(names: Optional[List[AnyStr]] = None, *, df=None, count: Optional[int] = None, begin_edit: Optional[bool] = None, **kwargs: typing_extensions.Unpack[altdss.UPFC.UPFCBatchProperties]) altdss.UPFC.UPFCBatch#

Creates a new batch of UPFC objects

Either names, count or df is required.

Parameters:
  • begin_edit – The argument begin_edit indicates if the user want to leave the elements in the edit state, and requires a call to end_edit() or equivalent. The default begin_edit is set to None. With None, the behavior will be adjusted according the default of how the batch is created.

  • **kwargs – Pass keyword arguments equivalent to the DSS properties of the object.

  • names – When using a list of names, each new object will match the names from this list. begin_edit defaults to True if no arguments for properties were passed, False otherwise.

  • count – When using count, new objects will be created with based on a random prefix, with an increasing integer up to count. begin_edit defaults to True if no arguments for properties were passed, False otherwise.

  • df – Currently EXPERIMENTAL AND LIMITED, tries to get the columns from a dataframe to populate the names and the DSS properties. begin_edit defaults to False.

Returns:

Returns the new batch of DSS objects, wrapped in Python.

Note that, to make it easier for new users where the edit context might not be too relevant, AltDSS automatically opens/closes edit contexts for single properties if the object is not in the edit state already.

begin_edit() None#

Marks for editing all DSS objects in the batch

In the editing mode, some final side-effects of changing properties are postponed until end_edit is called. This side-effects can be somewhat costly, like updating the model parameters or internal matrices.

If you don’t have any performance constraint, you may edit each property individually without worrying about using begin_edit and end_edit. For convenience, those are emitted automatically when editing single properties outside an edit block.

edit(**kwargs: typing_extensions.Unpack[altdss.UPFC.UPFCBatchProperties]) altdss.UPFC.UPFCBatch#

Edit this UPFC batch.

This method will try to open a new edit context (if not already open), edit the properties, and finalize the edit context for objects in the batch. It can be seen as a shortcut to manually setting each property, or a Pythonic analogous (but extended) to the DSS BatchEdit command.

Parameters:

**kwargs – Pass keyword arguments equivalent to the DSS properties of the objects.

Returns:

Returns itself to allow call chaining.

end_edit(num_changes: int = 1) None#

Leaves the editing states of all DSS objects in the batch

num_changes is required for a few classes to correctly match the official OpenDSS behavior and must be the number of properties modified in the current editing block. As of DSS C-API v0.13, this is only required for the Monitor class, when the Action property is used with the Process value.

find(name_or_idx: Union[AnyStr, int]) altdss.DSSObj.DSSObj#

Returns an object from the collection by name or index; the index must be zero-based.

kvarLimit: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Maximum amount of reactive power (kvar) that can be absorbed by the UPFC (Default = 5)

DSS property name: kvarLimit, DSS property index: 16.

new(name: AnyStr, *, begin_edit: Optional[bool] = None, activate=False, **kwargs: typing_extensions.Unpack[altdss.UPFC.UPFCProperties]) altdss.UPFC.UPFC#

Creates a new UPFC.

Parameters:
  • name – The object’s name is a required positional argument.

  • activate – Activation (setting activate to true) is useful for integration with the classic API, and some internal OpenDSS commands. If you interact with this object only via the Alt API, no need to activate it (due to performance costs).

  • begin_edit – This controls how the edit context is left after the object creation:

  • True: The object will be left in the edit state, requiring an end_edit call or equivalent.

  • False: No edit context is started.

  • None: If no properties are passed as keyword arguments, the object will be left in the edit state (assumes the user will fill the properties from Python attributes). Otherwise, the internal edit context will be finalized.

Parameters:

**kwargs – Pass keyword arguments equivalent to the DSS properties of the object.

Returns:

Returns the new DSS object, wrapped in Python.

Note that, to make it easier for new users where the edit context might not be too relevant, AltDSS automatically opens/closes edit contexts for single properties if the object is not in the edit state already.

refkV2: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Base Voltage expected at the output of the UPFC for control modes 4 and 5.

This reference must be lower than refkv, see control modes 4 and 5 for details

DSS property name: refkV2, DSS property index: 15.

to_json(options: Union[int, dss.enums.DSSJSONFlags] = 0)#

Returns the data (as a list) of the elements in a batch as a JSON-encoded string.

The options parameter contains bit-flags to toggle specific features. See Obj_ToJSON (C-API) for more, or DSSObj.to_json in Python.

Additionally, the ExcludeDisabled flag can be used to excluded disabled elements from the output.

to_list()#
altdss.UPFC.PDElement#

None

class altdss.UPFC.UPFC(api_util, ptr)#

Bases: altdss.DSSObj.DSSObj, altdss.CircuitElement.CircuitElementMixin, altdss.PCElement.PCElementMixin

BaseFreq: float#

‘property(…)’

Base Frequency for ratings.

DSS property name: BaseFreq, DSS property index: 19.

Bus1: str#

‘property(…)’

Name of bus to which the input terminal (1) is connected. bus1=busname.1.3 bus1=busname.1.2.3

DSS property name: Bus1, DSS property index: 1.

Bus2: str#

‘property(…)’

Name of bus to which the output terminal (2) is connected. bus2=busname.1.2 bus2=busname.1.2.3

DSS property name: Bus2, DSS property index: 2.

CLimit: float#

‘property(…)’

Current Limit for the UPFC, if the current passing through the UPFC is higher than this value the UPFC turns off. This value is specified in Amps (Default 265 A)

DSS property name: CLimit, DSS property index: 14.

Close(terminal: int, phase: int) None#

Close the specified terminal and phase, if non-zero, or all conductors at the terminal.

Original COM help: https://opendss.epri.com/Close1.html

ComplexSeqCurrents() altdss.types.ComplexArray#

Complex double array of Sequence Currents for all conductors of all terminals of active circuit element.

Original COM help: https://opendss.epri.com/CplxSeqCurrents.html

ComplexSeqVoltages() altdss.types.ComplexArray#

Complex double array of Sequence Voltage for all terminals of active circuit element.

Original COM help: https://opendss.epri.com/CplxSeqVoltages1.html

Currents() altdss.types.ComplexArray#

Complex array of currents into each conductor of each terminal

Original COM help: https://opendss.epri.com/Currents1.html

DisplayName: str#

‘property(…)’

Display name of the object (not necessarily unique)

Original COM help: https://opendss.epri.com/DisplayName.html

Element: altdss.UPFC.PDElement#

‘property(…)’

The name of the PD element monitored when operating with reactive power compensation. Normally, it should be the PD element immediately upstream the UPFC. The element must be defined including the class, e.g. Line.myline.

DSS property name: Element, DSS property index: 17.

Element_str: str#

‘property(…)’

The name of the PD element monitored when operating with reactive power compensation. Normally, it should be the PD element immediately upstream the UPFC. The element must be defined including the class, e.g. Line.myline.

DSS property name: Element, DSS property index: 17.

Enabled: bool#

‘property(…)’

{Yes|No or True|False} Indicates whether this element is enabled.

DSS property name: Enabled, DSS property index: 20.

EnergyMeter() altdss.DSSObj.DSSObj#

Energy Meter this element is assigned to.

Requires an energy meter with an updated zone.

Original COM help: https://opendss.epri.com/EnergyMeter.html

EnergyMeterName() str#

Name of the Energy Meter this element is assigned to.

Requires an energy meter with an updated zone.

Original COM help: https://opendss.epri.com/EnergyMeter.html

Frequency: float#

‘property(…)’

UPFC working frequency. Defaults to system default base frequency.

DSS property name: Frequency, DSS property index: 5.

FullName() str#
GUID() str#

Object’s GUID/UUID. Currently used only in the CIM-related methods.

Original COM help: https://opendss.epri.com/GUID.html

GetVariableValue(varIdxName: Union[AnyStr, int]) float#
Handle() int#

Index of this element into the circuit’s element list.

Original COM help: https://opendss.epri.com/Handle.html

HasOCPDevice() bool#

Returns true if a recloser, relay, or fuse controlling the circuit element.

OCP = Overcurrent Protection

Original COM help: https://opendss.epri.com/HasOCPDevice.html

HasSwitchControl() bool#

Returns true if the element has a SwtControl attached.

Original COM help: https://opendss.epri.com/HasSwitchControl.html

HasVoltControl() bool#

Returns true if the element has a CapControl or RegControl attached.

Original COM help: https://opendss.epri.com/HasVoltControl.html

IsIsolated() bool#

Returns true if the element is isolated. Note that this only fetches the current value. See also the Topology interface.

IsOpen(terminal: int, phase: int) bool#

Returns true if the specified terminal and phase are open.

If the phase parameter is zero, returns if any conductor at the terminal is open.

Like(value: AnyStr)#

Make like another object, e.g.:

New Capacitor.C2 like=c1 …

DSS property name: Like, DSS property index: 21.

LossCurve: altdss.XYcurve.XYcurve#

‘property(…)’

Name of the XYCurve for describing the losses behavior as a function of the voltage at the input of the UPFC

DSS property name: LossCurve, DSS property index: 11.

LossCurve_str: str#

‘property(…)’

Name of the XYCurve for describing the losses behavior as a function of the voltage at the input of the UPFC

DSS property name: LossCurve, DSS property index: 11.

Losses() complex#

Total (complex) losses in the element, in VA (watts, vars)

Original COM help: https://opendss.epri.com/Losses1.html

MaxCurrent(terminal: int) float#

Returns the maximum current (magnitude) at the specified terminal. Use -1 as terminal to get the value across all terminals.

Mode: altdss.enums.UPFCMode#

‘property(…)’

Integer used to define the control mode of the UPFC:

0 = Off, 1 = Voltage regulator, 2 = Phase angle regulator, 3 = Dual mode 4 = It is a control mode where the user can set two different set points to create a secure GAP, these references must be defined in the parameters RefkV and RefkV2. The only restriction when setting these values is that RefkV must be higher than RefkV2. 5 = In this mode the user can define the same GAP using two set points as in control mode 4. The only difference between mode 5 and mode 4 is that in mode 5, the UPFC controller performs dual control actions just as in control mode 3

DSS property name: Mode, DSS property index: 9.

property Name: str#
NodeOrder() altdss.types.Int32Array#

Array of integer containing the node numbers (representing phases, for example) for each conductor of each terminal.

Be sure to run a solution to initialize the values after the circuit is created or modified.

NodeRef() altdss.types.Int32Array#

Array of integers, a copy of the internal NodeRef of the CktElement.

Be sure to run a solution to initialize the values after the circuit is created or modified.

NumConductors() int#

Number of conductors per terminal

Original COM help: https://opendss.epri.com/NumConductors.html

NumControllers() int#

Number of controllers connected to this device.

Original COM help: https://opendss.epri.com/NumControls.html

NumPhases() int#

Number of phases

Original COM help: https://opendss.epri.com/NumPhases.html

NumTerminals() int#

Number of terminals in this circuit element

Original COM help: https://opendss.epri.com/NumTerminals.html

OCPDevice() Union[altdss.DSSObj.DSSObj, None]#

Returns (as a Python object) the OCP device controlling this element, if any.

OCPDeviceIndex() int#

Index into controller list of OCP Device controlling this circuit element

Original COM help: https://opendss.epri.com/OCPDevIndex.html

OCPDeviceType() dss.enums.OCPDevType#

Type of OCP controller device

Original COM help: https://opendss.epri.com/OCPDevType.html

Open(terminal: int, phase: int) None#

Open the specified terminal and phase, if non-zero, or all conductors at the terminal.

Original COM help: https://opendss.epri.com/Open1.html

PF: float#

‘property(…)’

Power factor target at the input terminal.

DSS property name: PF, DSS property index: 4.

PhaseLosses() altdss.types.ComplexArray#

Complex array of losses (kVA) by phase

Original COM help: https://opendss.epri.com/PhaseLosses.html

Phases: int#

‘property(…)’

Number of phases. Defaults to 1 phase (2 terminals, 1 conductor per terminal).

DSS property name: Phases, DSS property index: 6.

Powers() altdss.types.ComplexArray#

Complex array of powers (kVA) into each conductor of each terminal

Original COM help: https://opendss.epri.com/Powers.html

RefkV: float#

‘property(…)’

Base Voltage expected at the output of the UPFC

“refkv=0.24”

DSS property name: RefkV, DSS property index: 3.

Residuals() altdss.types.Float64Array#

Residual currents for each terminal: (magnitude, angle in degrees)

Original COM help: https://opendss.epri.com/Residuals.html

SeqCurrents() altdss.types.Float64Array#

Array of symmetrical component currents (magnitudes only) into each 3-phase terminal

Original COM help: https://opendss.epri.com/SeqCurrents.html

SeqPowers() altdss.types.ComplexArray#

Complex array of sequence powers (kW, kvar) into each 3-phase terminal

Original COM help: https://opendss.epri.com/SeqPowers.html

SeqVoltages() altdss.types.Float64Array#

Double array of symmetrical component voltages (magnitudes only) at each 3-phase terminal

Original COM help: https://opendss.epri.com/SeqVoltages1.html

SetVariableValue(varIdxName: Union[AnyStr, int], value: float)#
Spectrum: altdss.Spectrum.Spectrum#

‘property(…)’

Name of harmonic spectrum for this source. Default is “defaultUPFC”, which is defined when the DSS starts.

DSS property name: Spectrum, DSS property index: 18.

Spectrum_str: str#

‘property(…)’

Name of harmonic spectrum for this source. Default is “defaultUPFC”, which is defined when the DSS starts.

DSS property name: Spectrum, DSS property index: 18.

Tol1: float#

‘property(…)’

Tolerance in pu for the series PI controller Tol1=0.02 is the format used to define 2% tolerance (Default=2%)

DSS property name: Tol1, DSS property index: 8.

TotalPowers() altdss.types.ComplexArray#

Returns an array with the total powers (complex, kVA) at ALL terminals of the active circuit element.

Original COM help: https://opendss.epri.com/TotalPowers.html

VHLimit: float#

‘property(…)’

High limit for the voltage at the input of the UPFC, if the voltage is above this value the UPFC turns off. This value is specified in Volts (default 300 V)

DSS property name: VHLimit, DSS property index: 12.

VLLimit: float#

‘property(…)’

low limit for the voltage at the input of the UPFC, if voltage is below this value the UPFC turns off. This value is specified in Volts (default 125 V)

DSS property name: VLLimit, DSS property index: 13.

VariableNames() List[str]#
VariableValues() altdss.types.Float64Array#
VariablesDict() Dict[str, float]#
Voltages() altdss.types.ComplexArray#

Complex array of voltages at terminals

Original COM help: https://opendss.epri.com/Voltages1.html

VoltagesMagAng() altdss.types.Float64Array#

Voltages at each conductor in magnitude, angle form as array of doubles.

Original COM help: https://opendss.epri.com/VoltagesMagAng.html

VpqMax: float#

‘property(…)’

Maximum voltage (in volts) delivered by the series voltage source (Default = 24 V)

DSS property name: VpqMax, DSS property index: 10.

Xs: float#

‘property(…)’

Reactance of the series transformer of the UPFC, ohms (default=0.7540 … 2 mH)

DSS property name: Xs, DSS property index: 7.

YPrim() altdss.types.ComplexArray#

YPrim matrix, column order, complex numbers

Original COM help: https://opendss.epri.com/Yprim.html

__hash__()#

Return hash(self).

__init__(api_util, ptr)#
__ne__(other)#

Return self!=value.

__repr__()#

Return repr(self).

begin_edit() None#

Marks a DSS object for editing

In the editing mode, some final side-effects of changing properties are postponed until end_edit is called. This side-effects can be somewhat costly, like updating the model parameters or internal matrices.

If you don’t have any performance constraint, you may edit each property individually without worrying about using begin_edit and end_edit. For convenience, those are emitted automatically when editing single properties outside an edit block.

edit(**kwargs: typing_extensions.Unpack[altdss.UPFC.UPFCProperties]) altdss.UPFC.UPFC#

Edit this UPFC.

This method will try to open a new edit context (if not already open), edit the properties, and finalize the edit context. It can be seen as a shortcut to manually setting each property, or a Pythonic analogous (but extended) to the DSS Edit command.

Parameters:

**kwargs – Pass keyword arguments equivalent to the DSS properties of the object.

Returns:

Returns itself to allow call chaining.

end_edit(num_changes: int = 1) None#

Leaves the editing state of a DSS object

num_changes is required for a few classes to correctly match the official OpenDSS behavior and must be the number of properties modified in the current editing block. As of DSS C-API v0.13, this is only required for the Monitor class, when the Action property is used with the Process value.

kvarLimit: float#

‘property(…)’

Maximum amount of reactive power (kvar) that can be absorbed by the UPFC (Default = 5)

DSS property name: kvarLimit, DSS property index: 16.

refkV2: float#

‘property(…)’

Base Voltage expected at the output of the UPFC for control modes 4 and 5.

This reference must be lower than refkv, see control modes 4 and 5 for details

DSS property name: refkV2, DSS property index: 15.

to_json(options: Union[int, dss.enums.DSSJSONFlags] = 0)#

Returns an element’s data as a JSON-encoded string.

The options parameter contains bit-flags to toggle specific features.

By default (options = 0), only the properties explicitly set. The properties are returned in the order they are set in the input. As a reminder, OpenDSS is sensitive to the order of the properties.

The options bit-flags are available in the DSSJSONFlags enum. Values used by this function are:

  • Full: if set, all properties are returned, ordered by property index instead.

  • SkipRedundant: if used with Full, all properties except redundant and unused ones are returned.

  • EnumAsInt: enumerated properties are returned as integer values instead of strings.

  • FullNames: any element reference will use the full name ({class name}.{element name}) even if not required.

  • Pretty: more whitespace is used in the output for a “prettier” format.

  • SkipDSSClass: do not add the “DSSClass” property to the JSON objects.

NOT IMPLEMENTED YET:

  • State: include run-time state information

  • Debug: include debug information

Other bit-flags are reserved for future uses. Please use DSSJSONFlags enum to avoid potential conflicts.

(API Extension)

class altdss.UPFC.UPFCBatch(api_util, **kwargs)#

Bases: altdss.Batch.DSSBatch, altdss.CircuitElement.CircuitElementBatchMixin, altdss.PCElement.PCElementBatchMixin

BaseFreq: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Base Frequency for ratings.

DSS property name: BaseFreq, DSS property index: 19.

Bus1: List[str]#

‘property(…)’

Name of bus to which the input terminal (1) is connected. bus1=busname.1.3 bus1=busname.1.2.3

DSS property name: Bus1, DSS property index: 1.

Bus2: List[str]#

‘property(…)’

Name of bus to which the output terminal (2) is connected. bus2=busname.1.2 bus2=busname.1.2.3

DSS property name: Bus2, DSS property index: 2.

CLimit: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Current Limit for the UPFC, if the current passing through the UPFC is higher than this value the UPFC turns off. This value is specified in Amps (Default 265 A)

DSS property name: CLimit, DSS property index: 14.

ComplexSeqCurrents() altdss.types.ComplexArray#

Complex double array of Sequence Currents for all conductors of all terminals of active circuit element.

Original COM help: https://opendss.epri.com/CplxSeqCurrents.html

ComplexSeqVoltages() altdss.types.ComplexArray#

Complex double array of Sequence Voltage for all terminals of active circuit element.

Original COM help: https://opendss.epri.com/CplxSeqVoltages1.html

Currents() altdss.types.ComplexArray#

Complex array of currents into each conductor of each terminal

Original COM help: https://opendss.epri.com/Currents1.html

CurrentsMagAng() altdss.types.Float64Array#

Currents in magnitude, angle (degrees) format as a array of doubles.

Original COM help: https://opendss.epri.com/CurrentsMagAng.html

Element: List[altdss.UPFC.PDElement]#

‘property(…)’

The name of the PD element monitored when operating with reactive power compensation. Normally, it should be the PD element immediately upstream the UPFC. The element must be defined including the class, e.g. Line.myline.

DSS property name: Element, DSS property index: 17.

Element_str: List[str]#

‘property(…)’

The name of the PD element monitored when operating with reactive power compensation. Normally, it should be the PD element immediately upstream the UPFC. The element must be defined including the class, e.g. Line.myline.

DSS property name: Element, DSS property index: 17.

Enabled: List[bool]#

‘property(…)’

{Yes|No or True|False} Indicates whether this element is enabled.

DSS property name: Enabled, DSS property index: 20.

EnergyMeter() List[altdss.DSSObj.DSSObj]#
EnergyMeterName() List[str]#
Frequency: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

UPFC working frequency. Defaults to system default base frequency.

DSS property name: Frequency, DSS property index: 5.

FullName() List[str]#

Returns the full name (including object type) for all objects in this batch

GUID() List[str]#

GUID/UUID for each object. Currently used only in the CIM-related methods.

Original COM help: https://opendss.epri.com/GUID.html

Handle() altdss.types.Int32Array#

Index of each element into the circuit’s element list.

Original COM help: https://opendss.epri.com/Handle.html

HasOCPDevice() altdss.types.BoolArray#

For each element in the batch: returns true if a recloser, relay, or fuse controlling the circuit element.

OCP = Overcurrent Protection

Original COM help: https://opendss.epri.com/HasOCPDevice.html

HasSwitchControl() altdss.types.BoolArray#

For each element in the batch: returns true if the element has a SwtControl attached.

Original COM help: https://opendss.epri.com/HasSwitchControl.html

HasVoltControl() altdss.types.BoolArray#

For each element in the batch: returns true if the element has a CapControl or RegControl attached.

Original COM help: https://opendss.epri.com/HasVoltControl.html

IsIsolated() altdss.types.BoolArray#

For each element in the batch: returns true if the element is isolated. Note that this only fetches the current value. See also the Topology interface.

Like(value: AnyStr, flags: altdss.enums.SetterFlags = 0)#

Make like another object, e.g.:

New Capacitor.C2 like=c1 …

DSS property name: Like, DSS property index: 21.

LossCurve: List[altdss.XYcurve.XYcurve]#

‘property(…)’

Name of the XYCurve for describing the losses behavior as a function of the voltage at the input of the UPFC

DSS property name: LossCurve, DSS property index: 11.

LossCurve_str: List[str]#

‘property(…)’

Name of the XYCurve for describing the losses behavior as a function of the voltage at the input of the UPFC

DSS property name: LossCurve, DSS property index: 11.

Losses() altdss.types.ComplexArray#

For each element in the batch: total losses in the element, in VA (watts, vars).

Original COM help: https://opendss.epri.com/Losses1.html

MaxCurrent(terminal: int) altdss.types.Float64Array#

Returns the maximum current (magnitude) at the specified terminal for each element in this batch. Use -1 as terminal to get the value across all terminals.

Mode: altdss.ArrayProxy.BatchInt32ArrayProxy#

‘property(…)’

Integer used to define the control mode of the UPFC:

0 = Off, 1 = Voltage regulator, 2 = Phase angle regulator, 3 = Dual mode 4 = It is a control mode where the user can set two different set points to create a secure GAP, these references must be defined in the parameters RefkV and RefkV2. The only restriction when setting these values is that RefkV must be higher than RefkV2. 5 = In this mode the user can define the same GAP using two set points as in control mode 4. The only difference between mode 5 and mode 4 is that in mode 5, the UPFC controller performs dual control actions just as in control mode 3

DSS property name: Mode, DSS property index: 9.

property Name: List[str]#
NumConductors() altdss.types.Int32Array#

Number of conductors per terminal for each element in the batch.

Original COM help: https://opendss.epri.com/NumConductors.html

NumControllers() altdss.types.Int32Array#

Number of controllers connected to each device in the batch.

Original COM help: https://opendss.epri.com/NumControls.html

NumPhases() altdss.types.Int32Array#

Number of Phases for each element in this batch.

Original COM help: https://opendss.epri.com/NumPhases.html

NumTerminals() altdss.types.Int32Array#

Number of terminals for each Circuit Element in the batch.

Original COM help: https://opendss.epri.com/NumTerminals.html

OCPDevice() List[Union[altdss.DSSObj.DSSObj, None]]#

Returns (as a list of Python objects) the OCP device controlling each element.

OCPDeviceIndex() altdss.types.Int32Array#

For each element in the batch: index into each controller list of the OCP Device controlling each circuit element

Original COM help: https://opendss.epri.com/OCPDevIndex.html

OCPDeviceType() List[dss.enums.OCPDevType]#

For each element in the batch: type of OCP controller device

Original COM help: https://opendss.epri.com/OCPDevType.html

PF: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Power factor target at the input terminal.

DSS property name: PF, DSS property index: 4.

PhaseLosses() altdss.types.ComplexArray#

Complex array of losses (kVA) by phase

Original COM help: https://opendss.epri.com/PhaseLosses.html

Phases: altdss.ArrayProxy.BatchInt32ArrayProxy#

‘property(…)’

Number of phases. Defaults to 1 phase (2 terminals, 1 conductor per terminal).

DSS property name: Phases, DSS property index: 6.

Powers() altdss.types.ComplexArray#

Complex array of powers (kVA) into each conductor of each terminal, of each element in the batch.

Original COM help: https://opendss.epri.com/Powers.html

RefkV: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Base Voltage expected at the output of the UPFC

“refkv=0.24”

DSS property name: RefkV, DSS property index: 3.

SeqCurrents() altdss.types.Float64Array#

Array of symmetrical component currents (magnitudes only) into each 3-phase terminal of each element

Original COM help: https://opendss.epri.com/SeqCurrents.html

SeqPowers() altdss.types.ComplexArray#

Complex array of sequence powers (kW, kvar) into each 3-phase terminal of each element

Original COM help: https://opendss.epri.com/SeqPowers.html

SeqVoltages() altdss.types.Float64Array#

Double array of symmetrical component voltages (magnitudes only) at each 3-phase terminal

Original COM help: https://opendss.epri.com/SeqVoltages1.html

Spectrum: List[altdss.Spectrum.Spectrum]#

‘property(…)’

Name of harmonic spectrum for this source. Default is “defaultUPFC”, which is defined when the DSS starts.

DSS property name: Spectrum, DSS property index: 18.

Spectrum_str: List[str]#

‘property(…)’

Name of harmonic spectrum for this source. Default is “defaultUPFC”, which is defined when the DSS starts.

DSS property name: Spectrum, DSS property index: 18.

Tol1: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Tolerance in pu for the series PI controller Tol1=0.02 is the format used to define 2% tolerance (Default=2%)

DSS property name: Tol1, DSS property index: 8.

TotalPowers() altdss.types.ComplexArray#

Returns an array with the total powers (complex, kVA) at all terminals of the circuit elements in this batch.

The resulting array is equivalent to concatenating the TotalPowers for each element.

VHLimit: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

High limit for the voltage at the input of the UPFC, if the voltage is above this value the UPFC turns off. This value is specified in Volts (default 300 V)

DSS property name: VHLimit, DSS property index: 12.

VLLimit: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

low limit for the voltage at the input of the UPFC, if voltage is below this value the UPFC turns off. This value is specified in Volts (default 125 V)

DSS property name: VLLimit, DSS property index: 13.

Voltages() altdss.types.ComplexArray#

Complex array of voltages at terminals

Original COM help: https://opendss.epri.com/Voltages1.html

VoltagesMagAng() altdss.types.Float64Array#

Voltages at each conductor in magnitude, angle form as array of doubles.

Original COM help: https://opendss.epri.com/VoltagesMagAng.html

VpqMax: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Maximum voltage (in volts) delivered by the series voltage source (Default = 24 V)

DSS property name: VpqMax, DSS property index: 10.

Xs: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Reactance of the series transformer of the UPFC, ohms (default=0.7540 … 2 mH)

DSS property name: Xs, DSS property index: 7.

__call__()#
__getitem__(idx0) altdss.DSSObj.DSSObj#

Get element at 0-based index of the batch pointer array

__init__(api_util, **kwargs)#
__iter__()#
__len__() int#
batch(**kwargs) altdss.Batch.DSSBatch#

Filter a batch using integer or float DSS properties, returning a new batch.

For integers, provide a single value to match.

For floats, provide a range as a 2-valued tuple/list (min value, max value), or an exact value to value (not recommended).

Multiple properties can be listed to allow filtering various conditions.

Example for loads:

    # Create an initial batch using a regular expression
    abc_loads = altdss.Load.batch(re=r'^abc.*$') # a batch of all loads with names starting with "abc"
    abc_loads_filtered = abc_loads.batch(Class=1, Phases=1, kV=(0.1, 1.0))

    # Create an initial batch, already filtered
    abc_loads_filtered = altdss.Load.batch(re=r'^abc.*$', Class=1, Phases=1, kV=(0.1, 1.0))
begin_edit() None#

Marks for editing all DSS objects in the batch

In the editing mode, some final side-effects of changing properties are postponed until end_edit is called. This side-effects can be somewhat costly, like updating the model parameters or internal matrices.

If you don’t have any performance constraint, you may edit each property individually without worrying about using begin_edit and end_edit. For convenience, those are emitted automatically when editing single properties outside an edit block.

edit(**kwargs: typing_extensions.Unpack[altdss.UPFC.UPFCBatchProperties]) altdss.UPFC.UPFCBatch#

Edit this UPFC batch.

This method will try to open a new edit context (if not already open), edit the properties, and finalize the edit context for objects in the batch. It can be seen as a shortcut to manually setting each property, or a Pythonic analogous (but extended) to the DSS BatchEdit command.

Parameters:

**kwargs – Pass keyword arguments equivalent to the DSS properties of the objects.

Returns:

Returns itself to allow call chaining.

end_edit(num_changes: int = 1) None#

Leaves the editing states of all DSS objects in the batch

num_changes is required for a few classes to correctly match the official OpenDSS behavior and must be the number of properties modified in the current editing block. As of DSS C-API v0.13, this is only required for the Monitor class, when the Action property is used with the Process value.

kvarLimit: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Maximum amount of reactive power (kvar) that can be absorbed by the UPFC (Default = 5)

DSS property name: kvarLimit, DSS property index: 16.

refkV2: altdss.ArrayProxy.BatchFloat64ArrayProxy#

‘property(…)’

Base Voltage expected at the output of the UPFC for control modes 4 and 5.

This reference must be lower than refkv, see control modes 4 and 5 for details

DSS property name: refkV2, DSS property index: 15.

to_json(options: Union[int, dss.enums.DSSJSONFlags] = 0)#

Returns the data (as a list) of the elements in a batch as a JSON-encoded string.

The options parameter contains bit-flags to toggle specific features. See Obj_ToJSON (C-API) for more, or DSSObj.to_json in Python.

Additionally, the ExcludeDisabled flag can be used to excluded disabled elements from the output.

to_list()#
class altdss.UPFC.UPFCBatchProperties#

Bases: typing_extensions.TypedDict

dict() -> new empty dictionary dict(mapping) -> new dictionary initialized from a mapping object’s (key, value) pairs dict(iterable) -> new dictionary initialized as if via: d = {} for k, v in iterable: d[k] = v dict(**kwargs) -> new dictionary initialized with the name=value pairs in the keyword argument list. For example: dict(one=1, two=2)

BaseFreq: Union[float, altdss.types.Float64Array]#

None

Bus1: Union[AnyStr, List[AnyStr]]#

None

Bus2: Union[AnyStr, List[AnyStr]]#

None

CLimit: Union[float, altdss.types.Float64Array]#

None

Element: Union[AnyStr, altdss.UPFC.PDElement, List[AnyStr], List[altdss.UPFC.PDElement]]#

None

Enabled: bool#

None

Frequency: Union[float, altdss.types.Float64Array]#

None

Like: AnyStr#

None

LossCurve: Union[AnyStr, altdss.XYcurve.XYcurve, List[AnyStr], List[altdss.XYcurve.XYcurve]]#

None

Mode: Union[int, altdss.enums.UPFCMode, altdss.types.Int32Array]#

None

PF: Union[float, altdss.types.Float64Array]#

None

Phases: Union[int, altdss.types.Int32Array]#

None

RefkV: Union[float, altdss.types.Float64Array]#

None

Spectrum: Union[AnyStr, altdss.Spectrum.Spectrum, List[AnyStr], List[altdss.Spectrum.Spectrum]]#

None

Tol1: Union[float, altdss.types.Float64Array]#

None

VHLimit: Union[float, altdss.types.Float64Array]#

None

VLLimit: Union[float, altdss.types.Float64Array]#

None

VpqMax: Union[float, altdss.types.Float64Array]#

None

Xs: Union[float, altdss.types.Float64Array]#

None

__contains__()#

True if the dictionary has the specified key, else False.

__delattr__()#

Implement delattr(self, name).

__delitem__()#

Delete self[key].

__dir__()#

Default dir() implementation.

__format__()#

Default object formatter.

Return str(self) if format_spec is empty. Raise TypeError otherwise.

__ge__()#

Return self>=value.

__getattribute__()#

Return getattr(self, name).

__getitem__()#

Return self[key].

__getstate__()#

Helper for pickle.

__gt__()#

Return self>value.

__init__()#

Initialize self. See help(type(self)) for accurate signature.

__ior__()#

Return self|=value.

__iter__()#

Implement iter(self).

__le__()#

Return self<=value.

__len__()#

Return len(self).

__lt__()#

Return self<value.

__ne__()#

Return self!=value.

__new__()#

Create and return a new object. See help(type) for accurate signature.

__or__()#

Return self|value.

__reduce__()#

Helper for pickle.

__reduce_ex__()#

Helper for pickle.

__repr__()#

Return repr(self).

__reversed__()#

Return a reverse iterator over the dict keys.

__ror__()#

Return value|self.

__setitem__()#

Set self[key] to value.

__sizeof__()#

D.sizeof() -> size of D in memory, in bytes

__str__()#

Return str(self).

__subclasshook__()#

Abstract classes can override this to customize issubclass().

This is invoked early on by abc.ABCMeta.subclasscheck(). It should return True, False or NotImplemented. If it returns NotImplemented, the normal algorithm is used. Otherwise, it overrides the normal algorithm (and the outcome is cached).

clear()#

D.clear() -> None. Remove all items from D.

copy()#

D.copy() -> a shallow copy of D

get()#

Return the value for key if key is in the dictionary, else default.

items()#

D.items() -> a set-like object providing a view on D’s items

keys()#

D.keys() -> a set-like object providing a view on D’s keys

kvarLimit: Union[float, altdss.types.Float64Array]#

None

pop()#

D.pop(k[,d]) -> v, remove specified key and return the corresponding value.

If the key is not found, return the default if given; otherwise, raise a KeyError.

popitem()#

Remove and return a (key, value) pair as a 2-tuple.

Pairs are returned in LIFO (last-in, first-out) order. Raises KeyError if the dict is empty.

refkV2: Union[float, altdss.types.Float64Array]#

None

setdefault()#

Insert key with a value of default if key is not in the dictionary.

Return the value for key if key is in the dictionary, else default.

update()#

D.update([E, ]**F) -> None. Update D from dict/iterable E and F. If E is present and has a .keys() method, then does: for k in E: D[k] = E[k] If E is present and lacks a .keys() method, then does: for k, v in E: D[k] = v In either case, this is followed by: for k in F: D[k] = F[k]

values()#

D.values() -> an object providing a view on D’s values

class altdss.UPFC.UPFCProperties#

Bases: typing_extensions.TypedDict

dict() -> new empty dictionary dict(mapping) -> new dictionary initialized from a mapping object’s (key, value) pairs dict(iterable) -> new dictionary initialized as if via: d = {} for k, v in iterable: d[k] = v dict(**kwargs) -> new dictionary initialized with the name=value pairs in the keyword argument list. For example: dict(one=1, two=2)

BaseFreq: float#

None

Bus1: AnyStr#

None

Bus2: AnyStr#

None

CLimit: float#

None

Element: Union[AnyStr, altdss.UPFC.PDElement]#

None

Enabled: bool#

None

Frequency: float#

None

Like: AnyStr#

None

LossCurve: Union[AnyStr, altdss.XYcurve.XYcurve]#

None

Mode: Union[int, altdss.enums.UPFCMode]#

None

PF: float#

None

Phases: int#

None

RefkV: float#

None

Spectrum: Union[AnyStr, altdss.Spectrum.Spectrum]#

None

Tol1: float#

None

VHLimit: float#

None

VLLimit: float#

None

VpqMax: float#

None

Xs: float#

None

__contains__()#

True if the dictionary has the specified key, else False.

__delattr__()#

Implement delattr(self, name).

__delitem__()#

Delete self[key].

__dir__()#

Default dir() implementation.

__format__()#

Default object formatter.

Return str(self) if format_spec is empty. Raise TypeError otherwise.

__ge__()#

Return self>=value.

__getattribute__()#

Return getattr(self, name).

__getitem__()#

Return self[key].

__getstate__()#

Helper for pickle.

__gt__()#

Return self>value.

__init__()#

Initialize self. See help(type(self)) for accurate signature.

__ior__()#

Return self|=value.

__iter__()#

Implement iter(self).

__le__()#

Return self<=value.

__len__()#

Return len(self).

__lt__()#

Return self<value.

__ne__()#

Return self!=value.

__new__()#

Create and return a new object. See help(type) for accurate signature.

__or__()#

Return self|value.

__reduce__()#

Helper for pickle.

__reduce_ex__()#

Helper for pickle.

__repr__()#

Return repr(self).

__reversed__()#

Return a reverse iterator over the dict keys.

__ror__()#

Return value|self.

__setitem__()#

Set self[key] to value.

__sizeof__()#

D.sizeof() -> size of D in memory, in bytes

__str__()#

Return str(self).

__subclasshook__()#

Abstract classes can override this to customize issubclass().

This is invoked early on by abc.ABCMeta.subclasscheck(). It should return True, False or NotImplemented. If it returns NotImplemented, the normal algorithm is used. Otherwise, it overrides the normal algorithm (and the outcome is cached).

clear()#

D.clear() -> None. Remove all items from D.

copy()#

D.copy() -> a shallow copy of D

get()#

Return the value for key if key is in the dictionary, else default.

items()#

D.items() -> a set-like object providing a view on D’s items

keys()#

D.keys() -> a set-like object providing a view on D’s keys

kvarLimit: float#

None

pop()#

D.pop(k[,d]) -> v, remove specified key and return the corresponding value.

If the key is not found, return the default if given; otherwise, raise a KeyError.

popitem()#

Remove and return a (key, value) pair as a 2-tuple.

Pairs are returned in LIFO (last-in, first-out) order. Raises KeyError if the dict is empty.

refkV2: float#

None

setdefault()#

Insert key with a value of default if key is not in the dictionary.

Return the value for key if key is in the dictionary, else default.

update()#

D.update([E, ]**F) -> None. Update D from dict/iterable E and F. If E is present and has a .keys() method, then does: for k in E: D[k] = E[k] If E is present and lacks a .keys() method, then does: for k, v in E: D[k] = v In either case, this is followed by: for k in F: D[k] = F[k]

values()#

D.values() -> an object providing a view on D’s values